2015
DOI: 10.1016/j.talanta.2015.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative analysis of estradiol and six other steroid hormones in human saliva using a high throughput liquid chromatography–tandem mass spectrometry assay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
76
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 103 publications
(76 citation statements)
references
References 34 publications
0
76
0
Order By: Relevance
“…Potential reasons for this are that estradiol levels fluctuate along the day due to the circadian rhythm (Shirtcliff et al, 2000), between different cycles (Becker et al, 2005) and sometimes exhibits different pattern from woman to woman (Gandara et al, 2007). In addition, insufficient analytical accuracy in individual assays have already been reported (Gao et al, 2015) and other studies have also failed to replicate the expected pattern of estradiol along the menstrual cycle in salivary samples, although the correlation with serum estradiol was high (Lu et al, 1999). One explanation for this could be inter-individual differences in the metabolism of estradiol within the salivary glands (Lu et al, 1999).…”
Section: Discussionmentioning
confidence: 99%
“…Potential reasons for this are that estradiol levels fluctuate along the day due to the circadian rhythm (Shirtcliff et al, 2000), between different cycles (Becker et al, 2005) and sometimes exhibits different pattern from woman to woman (Gandara et al, 2007). In addition, insufficient analytical accuracy in individual assays have already been reported (Gao et al, 2015) and other studies have also failed to replicate the expected pattern of estradiol along the menstrual cycle in salivary samples, although the correlation with serum estradiol was high (Lu et al, 1999). One explanation for this could be inter-individual differences in the metabolism of estradiol within the salivary glands (Lu et al, 1999).…”
Section: Discussionmentioning
confidence: 99%
“…Early MALDI studies focused on the analysis of isolated (pure) peptides and proteins, but it was soon evident that complex mixtures could also be analyzed, and with the judicious selection of matrix, matrix formulation, and analyte concentration, almost all molecular types can be analyzed, including lipids (lipidomics) (9 ), carbohydrates (glycomics) (10 ), hormones (11,12 ), drugs and drug metabolites (13 ), and nucleotides and nucleosides (14 ).…”
Section: Evolution Of Maldi and Current Performance Characteristics Mmentioning
confidence: 99%
“…[50][51][52] The authors also describe the advantage of LC-MS/ MS compared to immunoassay in relation to sensitivity. [50][51][52] The authors also describe the advantage of LC-MS/ MS compared to immunoassay in relation to sensitivity.…”
Section: Hormone Quantificationmentioning
confidence: 99%
“…Recent studies have shown that LC-MS/MS could reliably and accurately detect salivary testosterone in males as well as in females. [50][51][52] The authors also describe the advantage of LC-MS/ MS compared to immunoassay in relation to sensitivity. Gao et al postulated a linear range of all steroid measurements of 0.001-10 ng/mL, exceeding the linearity range of the used immunoassay in the present study (0.007 -4.5 ng/mL).…”
Section: Correlation Of Salivary Testosterone Concentrationmentioning
confidence: 99%