Quantitative and rapid detection of morphine and hydromorphone at the point of care by an automated giant magnetoresistive nanosensor platform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 59 publications
0
5
0
Order By: Relevance
“…The CV values were calculated to be 2.0, 3.7, and 2.5% at MOP concentrations of 1, 10, and 200 ng/mL, respectively (Figure e). The results in Figure e demonstrate the good intrabatch repeatability of this platform, enabling highly accurate quantification of MOP in urine …”
Section: Resultsmentioning
confidence: 75%
“…The CV values were calculated to be 2.0, 3.7, and 2.5% at MOP concentrations of 1, 10, and 200 ng/mL, respectively (Figure e). The results in Figure e demonstrate the good intrabatch repeatability of this platform, enabling highly accurate quantification of MOP in urine …”
Section: Resultsmentioning
confidence: 75%
“…Cortade and coworkers [75] detailed their work on developing a giant magnetoresistive nanosensor array (GMR) for the dual-use detection of morphine and hydromorphone in saliva, blood, and plasma. The fabricated array was comprised of an array of 80 independent sensors on a square 5 × 5 mm chip that was bound to a printed circuit board with wire.…”
Section: Biosensors Detection 21 Bisosensors Detection Of Pharmaceuti...mentioning
confidence: 99%
“…The resultant device was not only easy to manufacture but also multiplexable, supported the point-of-care quantification needs over a wide range of concentrations, and allowed for detecting the analytes in saliva, whole blood, and plasma. In addition, less than 200 mL of sample is needed for analysis, which is essential because a limiting factor for accurate analysis may be sample size [75]. Biological samples are essential targets for ever-developing screening tools, which can help researchers gain an understanding of the metabolic impact of opioid use and allow for greater variation in the types of samples that can be tested to determine opioid concentrations or to confirm drug presence.…”
Section: Biosensors Detection 21 Bisosensors Detection Of Pharmaceuti...mentioning
confidence: 99%
“…Giant magnetoresistance (GMR) bead-based biosensors utilize the changes in resistance resulting from the binding events between the target biomarker and the bead-bound capture molecule. The beads are functionalized with capture molecules, and when the target biomarker binds, it induces changes in the magnetic field around the GMR sensor, leading to changes in resistance [154]. The resistance change is then measured and correlated with the concentration of the target biomarker.…”
Section: Magnetic Biosensorsmentioning
confidence: 99%