2022
DOI: 10.5603/oj.2022.0002
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative assessment of optic disc photographs in normal and open-angle glaucoma patients

Abstract: Open-angle glaucoma is a progressive optic neuropathy characterized by retinal ganglion cell loss and structural changes in the retinal nerve fiber layer (RNFL) and optic nerve head (ONH) that may lead to visual field loss [1]. Diagnosis of glaucomatous This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…As long as the ametropia of the eye does not exceed 5 D, the distance at which the condensing lens is held does not statistically significantly affect the measurements of the optic disc. While some studies indicate that ametropia does not exceed 3 D, others have found a good association for myopia up to -8 D (Abdellaoui et al, 2022). The slit lamp condensing lens system's high magnification reduces the field depth, lowering measurement errors.…”
Section: Technique Average Diametermentioning
confidence: 99%
See 3 more Smart Citations
“…As long as the ametropia of the eye does not exceed 5 D, the distance at which the condensing lens is held does not statistically significantly affect the measurements of the optic disc. While some studies indicate that ametropia does not exceed 3 D, others have found a good association for myopia up to -8 D (Abdellaoui et al, 2022). The slit lamp condensing lens system's high magnification reduces the field depth, lowering measurement errors.…”
Section: Technique Average Diametermentioning
confidence: 99%
“…The clinical appearance of the optic nerve is measured by fundus photographs and slit lamp measurements, while the scleral canal is measured by HRT utilizing variations in the laser's reflectivity. Lim discovered a strong association between the two measuring methods when he compared fundus lens readings to HRT measurements (Abdellaoui et al, 2022). According to studies, mean vertical diameter measurements taken with a noncontact fundus lens and slit lamp were equivalent to those taken with fundus photography and HRT (Mocan et al, 2020).…”
Section: Correlation Between Measurement Techniquesmentioning
confidence: 99%
See 2 more Smart Citations