2010
DOI: 10.1208/s12249-009-9357-4
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Determination of Hydrate Content of Theophylline Powder by Chemometric X-ray Powder Diffraction Analysis

Abstract: Abstract. The purpose of this study was to establish a calibration model to predict the hydrate content in powder materials consisting of anhydrate (theophylline anhydrate (THA)) and theophylline monohydrate (THM) by using various kinds of X-ray powder diffraction (XRPD) analytical methods. XRPD profiles were measured five times each for 11 standard samples containing of THA and THM. THM content in the standard samples was evaluated based on XRPD profiles by the diffraction peak height and area methods, and th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Otsuka and Kinoshita 13) applied PLS to PXRD patterns and constructed an accurate calibration model for theophylline hydrate.…”
mentioning
confidence: 99%
“…Otsuka and Kinoshita 13) applied PLS to PXRD patterns and constructed an accurate calibration model for theophylline hydrate.…”
mentioning
confidence: 99%
“…Powder XRD identifies hydrates through peaks associated with the hydrate structure, which is different from the anhydrous material and also from other hydrates with a different stoichiometric ratio. The technique is qualitative in general, although a suitable sample preparation and a careful analysis can yield quantitative information as well. NIR, often in conjunction with Raman spectroscopy, is also popular. , Here vibrational modes of the molecules in a hydrate and anhydrate can be distinguished, as hydrates include additional features, mainly the O–H vibrational modes which are detected by NIR. The method is again qualitative in general, although it can provide quantitative information, but since the NIR spectrum is a convolution of chemical and physical interactions between the sample and NIR radiation, the level of detection and precision will depend very much on the spectral characteristics of the components and on the sampling technique. , …”
mentioning
confidence: 99%
“…THM content in the standard samples was evaluated based on XRPD profiles by the diffraction peak height and area methods and the Wakelin's and principal component regression (PCR) methods. In the result based on validation XRPD datasets, the order of the mean bias and the mean accuracy was peak height > peak area > Wakelin's > PCR, indicating that PCR was the best method to correct sample crystal orientation [76].…”
Section: Tablet Parametricmentioning
confidence: 96%