2001
DOI: 10.1093/jaoac/84.4.1099
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Determination of Paralytic Shellfish Poisoning Toxins in Shellfish by Using Prechromatographic Oxidation and Liquid Chromatography with Fluorescence Detection

Abstract: The prechromatographic oxidation LC method developed by Lawrence [J. Assoc. Off. Anal. Chem. 74, 404–409(1991)] for the determination of paralytic shellfish poisoning (PSP) toxins has been tested for the quantitative determination of PSP toxins in shellfish. All aspects of the method were studied and modified as necessary to improve its performance for routine regulatory purposes. The chromatographic conditions were changed to shorten analysis time. The oxidation reaction was tested for repeatability and the i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0
6

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 90 publications
(49 citation statements)
references
References 0 publications
0
43
0
6
Order By: Relevance
“…Samples from the 2013 event were analyzed for PST using HPLC with pre-column oxidation and fluorescence detection (Lawrence and Niedzwiadek, 2001) only. The HPLC system consisted of a Shimadzu (Tokyo, Japan) chromatograph equipped with an SCL-10A VP controller, LC-10 AD pump, SIL-10AF autosampler, CTO-10AS VP column oven, and RF-10A XL fluorescence detector.…”
Section: Paralytic Shellfish Toxins Analysesmentioning
confidence: 99%
See 1 more Smart Citation
“…Samples from the 2013 event were analyzed for PST using HPLC with pre-column oxidation and fluorescence detection (Lawrence and Niedzwiadek, 2001) only. The HPLC system consisted of a Shimadzu (Tokyo, Japan) chromatograph equipped with an SCL-10A VP controller, LC-10 AD pump, SIL-10AF autosampler, CTO-10AS VP column oven, and RF-10A XL fluorescence detector.…”
Section: Paralytic Shellfish Toxins Analysesmentioning
confidence: 99%
“…The HPLC system consisted of a Shimadzu (Tokyo, Japan) chromatograph equipped with an SCL-10A VP controller, LC-10 AD pump, SIL-10AF autosampler, CTO-10AS VP column oven, and RF-10A XL fluorescence detector. Sample clean-up and PST separations were performed as described in Lawrence and Niedzwiadek (2001). Certified reference standards of STX, NEO, dcSTX, B1, GTX 1/4, GTX 2/3, dcGTX-2/3, and C1/2 (National Research Council, Canada) were used for instrument calibration.…”
Section: Paralytic Shellfish Toxins Analysesmentioning
confidence: 99%
“…The toxins converted into the correspondent fluorescent derivatives were determined using HPLC-FLD based on the precolumn oxidation method developed by [18]. The HPLC-FLD equipment consisted of a Hewlett-Packard/Agilent Model 1050 quaternary pump, Model 1100 in-line degasser, autosampler, column oven, and Model 1200 fluorescence detector.…”
Section: High Performance Liquid Chromatography With Fluorescence Detmentioning
confidence: 99%
“…Se aplicó el método de análisis de toxinas paralizantes en cromatografía líquida de alta resolución (HPLC) con detección de fluorescencia, oxidación precolumna y con un gradiente binario. 19,20 Se realizó una extracción ácida de las toxinas paralizantes a partir de 5 g de tejido de molusco fresco homogenizado en muestras compuestas por zona (Santiago Astata Est. 1, 2 y 3, y Puerto Escondido Est.…”
Section: Determinación De Toxinas En Cromatografía Líquida De Alta Reunclassified