2008
DOI: 10.1016/j.chroma.2008.08.082
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative determination of salbutamol in tablets by multiple-injection capillary zone electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 26 publications
0
12
0
Order By: Relevance
“…chromatography [6], capillary electrophoresis [7,8], fluorescence spectrometry-related method [9], square wave voltammetry [10], and mass spectrometry [11][12][13]. However, these techniques are time consuming, tedious and require complicated pre-treatment procedures, and the high cost due to the adopted expensive instrument.…”
Section: Introductionmentioning
confidence: 98%
“…chromatography [6], capillary electrophoresis [7,8], fluorescence spectrometry-related method [9], square wave voltammetry [10], and mass spectrometry [11][12][13]. However, these techniques are time consuming, tedious and require complicated pre-treatment procedures, and the high cost due to the adopted expensive instrument.…”
Section: Introductionmentioning
confidence: 98%
“…Analytical methods hitherto reported for the determination of SAL include high performance liquid chromatography (Pichon, Venisse, Krupka, Perault-Pochat, & Denjean, 2006), gas chromatography-mass spectrometry (Ouyang et al, 2005), spectrophotometry (El-Enany, Bela, & Rizk, 2004;Basavaiah & Prameela, 2003), capillary electrophoresis (Felix et al, 2006;Sirichai & Khanatharana, 2008;Lodén, Pettersson, Arvidsson, & Amini, 2008), flowinjection analysis-chemiluminescence (Zhou, Zhang, He, & Xiong, 2005;Karuwan et al, 2009), immunosensor (Dudak & Boyaci, 2007) etc. Many of these techniques are expensive or require time-consuming derivatization steps (Pichon et al, 2006;Ouyang et al, 2005).…”
Section: Introductionmentioning
confidence: 99%
“…Four samples were injected with background electrolyte zones in between containing the sample of interest and an internal standard. Another multiple-injection capillary zone electrophoresis procedure (MICZE) has been elaborated for the assay of salbutamol [7]. In this method, seven sample sets, each consisting of three of the same samples, were sequentially injected into the capillary and analyzed within a single run.…”
Section: Introductionmentioning
confidence: 99%