2008
DOI: 10.1016/j.jchromb.2008.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative evaluation of sphingomyelin and glucosylceramide using matrix-assisted laser desorption ionization time-of-flight mass spectrometry with sphingosylphosphorylcholine as an internal standard

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 19 publications
0
20
0
Order By: Relevance
“…The resulting lyso-sulfatides were extracted with a C18 MicroTip and analyzed by MALDI-TOF from CHCA allowing quantitation of serum sulfatides from one hundred-to 50-mL serum specimens within 1 working day. A quantitative method has been described for ceramide monohexoside and sphingomyelin using sphingosylphosphorylcholine as the internal standard (Fujiwaki, Tasaka, & Yamaguchi, 2008) and DHB as the MALDI matrix. The calibration curve for ceramide monohexoside was linear over the range 5-150 ng and the method was used to measure accumulations of the glycolipids in liver and spleen samples from patients with Gaucher disease.…”
Section: Other Methodsmentioning
confidence: 99%
“…The resulting lyso-sulfatides were extracted with a C18 MicroTip and analyzed by MALDI-TOF from CHCA allowing quantitation of serum sulfatides from one hundred-to 50-mL serum specimens within 1 working day. A quantitative method has been described for ceramide monohexoside and sphingomyelin using sphingosylphosphorylcholine as the internal standard (Fujiwaki, Tasaka, & Yamaguchi, 2008) and DHB as the MALDI matrix. The calibration curve for ceramide monohexoside was linear over the range 5-150 ng and the method was used to measure accumulations of the glycolipids in liver and spleen samples from patients with Gaucher disease.…”
Section: Other Methodsmentioning
confidence: 99%
“…Sphingosylphosphorylcholine was used as the internal standard for quantification of sphingomyelin and ceramide monohexoside (CMH). The authors report that accumulated sphingomyelin and CMH in small amounts of tissues from sphingolipidosis patients can be quantified for diagnostic purposes and also for biochemical pathophysiology evaluation [58].…”
Section: Lipidsmentioning
confidence: 99%
“…MALDI-TOF/MS was also used to characterize lipid biomarkers extracted by organic solvent from human serum. After the major classes of lipoproteins were isolated from serum samples by ultracentrifugation, the lipids were extracted from lipoproteins by Folch's solution (chloroform/ methanol 2:1, v/v) and analyzed by MALDI-TOF/MS to determine lipid biomarkers such as sphingolipids in liver, spleen, and cardiac valve samples for Niemann-Pick disease, Gaucher disease, and Fabry disease, respectively [230][231][232]. Sphingosylphosphorylcholine was used as the internal standard for quantification of sphingomyelin and ceramidemonohexoside.…”
Section: Liquid-liquid Extractionmentioning
confidence: 99%
“…Sphingosylphosphorylcholine was used as the internal standard for quantification of sphingomyelin and ceramidemonohexoside. Accumulated sphingomyelin and ceramidemonohexoside in the tissues collected from sphingolipidosis patients were quantified for clinical diagnosis and for biochemical and pathophysiological evaluation [230,231]. Ceramide trihexose was detected at high concentrations in samples with Fabry disease [232].…”
Section: Liquid-liquid Extractionmentioning
confidence: 99%