2021
DOI: 10.3233/thc-218048
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative metabolic characteristics in the peritumoral region of gliomas at 7T

Abstract: BACKGROUND: The determination of tumor peripheral is of great significance in clinical diagnosis and treatment. OBJECTIVE: In this study, we aim to obtain the metabolic condition in tumor peripheral of gliomas in vivo at 7T. METHODS: C6 glioma cells were implanted into the right basal ganglia of Sprague-Dawley (SD) rats under stereotactic guided to create the glioma models. The models were sequentially undergone MRI and MRS examination on an 7T MR scanner designed for animals 7 days after the operation. Neuro … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…Chemical exchange saturation transfer (CEST)-MRI has been widely used in metabolite evaluation because of its sensitivity to the exchange process between molecules with exchangeable protons and bulk water protons. [1][2][3][4][5] Although CEST-MRI is powerful and versatile in the detection and research of tumors [6][7][8] and in renal [9][10][11] and cardiac imaging, 12 the CEST effect is limited by experimental conditions, such as the amplitude 13,14 and duration of RF saturation. 15,16 In fact, there are two competing processes in the CEST effect: signal reduction due to saturation transfer from irradiated labile protons and signal recovery through relaxation.…”
Section: Introductionmentioning
confidence: 99%
“…Chemical exchange saturation transfer (CEST)-MRI has been widely used in metabolite evaluation because of its sensitivity to the exchange process between molecules with exchangeable protons and bulk water protons. [1][2][3][4][5] Although CEST-MRI is powerful and versatile in the detection and research of tumors [6][7][8] and in renal [9][10][11] and cardiac imaging, 12 the CEST effect is limited by experimental conditions, such as the amplitude 13,14 and duration of RF saturation. 15,16 In fact, there are two competing processes in the CEST effect: signal reduction due to saturation transfer from irradiated labile protons and signal recovery through relaxation.…”
Section: Introductionmentioning
confidence: 99%