2009
DOI: 10.1021/ac901497g
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Multiplex Detection of Pathogen Biomarkers on Multichannel Waveguides

Abstract: No single biomarker can accurately predict disease. An ideal biodetection technology should be capable of the quantitative, reproducible, and sensitive detection of a limited suite of such molecules. To this end, we have developed a multiplex biomarker assay for protective antigen and lethal factor of the Bacillus anthracis lethal toxin using semiconductor quantum dots as the fluorescence reporters on our waveguide-based biosensor platform. The platform is extendable to a wide array of biomarkers, facilitating… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
51
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(52 citation statements)
references
References 15 publications
0
51
0
1
Order By: Relevance
“…Lipid micelles for use in waveguide experiments were prepared as described previously [2,5,13]. Briefly, 2 mM DOPC and 1% cap-biotinyl (mol/mol) were combined in a glass tube and the chloroform evaporated under argon gas.…”
Section: Lipid Micelle Preparationmentioning
confidence: 99%
See 3 more Smart Citations
“…Lipid micelles for use in waveguide experiments were prepared as described previously [2,5,13]. Briefly, 2 mM DOPC and 1% cap-biotinyl (mol/mol) were combined in a glass tube and the chloroform evaporated under argon gas.…”
Section: Lipid Micelle Preparationmentioning
confidence: 99%
“…Silicon oxynitride waveguides were purchased from nGimat (Norcross, GA), functional silicon dioxide surfaces were maintained by Spectrum Thin Films (Hauppauge, NY) and waveguides were cleaned/ prepared as described previously [2,3,8,13]. Briefly, waveguides were cleaned by sonication in a water bath for 5 min each in chloroform, ethanol, and then nanopure water.…”
Section: Waveguide Preparation and Flow Cell Assemblymentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, QDs have been used in a dual-parameter assay performed in a multichannel waveguide-based chip. The assay can be completed in 15 min [60]. Also, multiplexed testing of cancer biomarkers carcinoembryonic antigen, cancer antigen 125, and Her-2/Neu has been done in a microfluidic nanochip using microparticles as solid phase.…”
Section: Fluorescent Labelsmentioning
confidence: 99%