Quartz crystal microbalance coated with PEDOT–PSS/PVA nanofiber for a high-performance humidity sensor

Abstract: Abstract. Quartz crystal microbalance (QCM) coated with poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate mixed with polyvinyl alcohol (PEDOT–PSS/PVA) nanofiber has been fabricated as a humidity sensor using the electrospinning method. Three types of PEDOT–PSS/PVA nanofiber sensors are fabricated with different needle-to-collector electrospinning distances. The scanning electron microscope images confirm the presence of beads in the nanofiber structure. The results show that the sensor mass deposition… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 44 publications
(44 reference statements)
0
18
0
Order By: Relevance
“…The MES-4 sensor sensitivity of this work was about 35.3 Hz/%RH, so this indicates that the MES-4 sensor shows very good sensitivity compared with the results of some previous studies. quartz crystal microbalance (QCM) techniques [46,47]. In this study, a magnetoelastic sensor was used to detect humidity.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The MES-4 sensor sensitivity of this work was about 35.3 Hz/%RH, so this indicates that the MES-4 sensor shows very good sensitivity compared with the results of some previous studies. quartz crystal microbalance (QCM) techniques [46,47]. In this study, a magnetoelastic sensor was used to detect humidity.…”
Section: Resultsmentioning
confidence: 99%
“…A number of methods have been developed for humidity detection, including capacitance [39][40][41][42], resistance [14], optic [43], microwave [44], magnetoelastic [17][18][19], surface acoustic wave [45], and quartz crystal microbalance (QCM) techniques [46,47]. In this study, a magnetoelastic sensor was used to detect humidity.…”
Section: Discussionmentioning
confidence: 99%
“…PEDOT: PSS polymer commonly cast on indium tin oxide (ITO) substrate using spin-coating technique [28,29]. Electrospinning is another technique to cast PEDOT: PSS with the addition of poly (vinyl alcohol) or PVA as a flexible thin film [30][31][32][33]. In this study, we proposed a simple and low cost method to fabricate strain sening elements of strain sensor using PEDOT: PSS mixed PVA.…”
Section: Introductionmentioning
confidence: 99%
“…The QCM is basically a piezoelectric sensor platform employing acoustic-electric effects that can measure mass resolution down to the picogram level 25 . By modifying the QCM chip sensing area with appropriate sensing layers (e.g., polymers 2629 , metal oxides 30,31 , and some functional materials 32,33 ), specific analytes that are additionally deposited on its surface can induce a frequency shift, which can subsequently be translated into detected analyte mass according to the Sauerbrey equations 34 .…”
Section: Introductionmentioning