“…Apparatus and Procedure. Quaternary and ternary liquid−liquid equilibrium (LLE) measurements for the quaternary and ternary systems with TAME were carried out in the temperature range from 298 to 341 K. The same static glass cell apparatus and measurement style used in earlier work 6 was used in the measurements. Analysis of the equilibrium phases was done with an Agilent Technologies 6890N gas a Standard uncertainties (u) are u(T/K) = 0.2, u(w 1, organic ) = 0.001, u(w 2, organic ) = 0.002, u(w 3, organic ) = 0.003, u(w 1, aqueous ) = 0.008, u(w 2, aqueous ) = 0.008, u(w 3, aqueous ) = 0.002, and u(p/kPa) = 1. chromatograph equipped with two detectors and two columns.…”