2019
DOI: 10.1016/j.microc.2018.09.030
|View full text |Cite
|
Sign up to set email alerts
|

Quenched electrochemiluminescence sensor of ZnO@g-C3N4 modified glassy carbon electrode for fipronil determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 56 publications
(13 citation statements)
references
References 36 publications
1
12
0
Order By: Relevance
“…Yin, Chen, and Chen (2019) constructed a quenched electrochemiluminescence (ECL) sensor by shaping ZnO and g‐C 3 N 4 composites on GCE for fipronil analysis. The ZnO@g‐C 3 N 4 composites had strong ECL signal which was remarkably decreased with the presence of fipronil because of its quenching effects on ECL emission.…”
Section: Electrochemical Techniquesmentioning
confidence: 99%
“…Yin, Chen, and Chen (2019) constructed a quenched electrochemiluminescence (ECL) sensor by shaping ZnO and g‐C 3 N 4 composites on GCE for fipronil analysis. The ZnO@g‐C 3 N 4 composites had strong ECL signal which was remarkably decreased with the presence of fipronil because of its quenching effects on ECL emission.…”
Section: Electrochemical Techniquesmentioning
confidence: 99%
“…Modified working electrode carbon-nanotube (MWCNT)-glassy carbon electrodes (GCEs) (Montes et al, 2016), Graphite-polyurethane (GPU) composite electrode (Okumura et al, 2016), and ZnO@g-C3N4 modified glassy carbon electrode (Yin et al, 2019), and FeO.TiO2-CPE (Nurdin et al, 2019a) have been reported to be able to detect fipronil compounds in different samples. Although the modification of the electrode shows high sensitivity with a low detection limit, electrode modification is still an interesting study in the past year.…”
Section: Modification Of Working Electrodes Is An Important Part Of Dmentioning
confidence: 99%
“…In recent years, electrochemiluminescence (ECL) as a newly developed analytical method has obtained considerable attention from researchers because of its simple equipment, easy operation, fast response, and high sensitivity, 9,10 whose applied light is produced by the substance at excited state returning to the ground state. 11 Among the ECL systems, the luminescence system based Ru(bpy) 3 2+ has been mostly applied in various elds for its high luminescence efficiency, good solubility, high chemical stability, and regenerability.…”
Section: Introductionmentioning
confidence: 99%