2022
DOI: 10.3389/fonc.2022.838155
|View full text |Cite
|
Sign up to set email alerts
|

Radial Data Mining to Identify Density–Dose Interactions That Predict Distant Failure Following SABR

Abstract: PurposeLower dose outside the planned treatment area in lung stereotactic radiotherapy has been linked to increased risk of distant metastasis (DM) possibly due to underdosage of microscopic disease (MDE). Independently, tumour density on pretreatment computed tomography (CT) has been linked to risk of MDE. No studies have investigated the interaction between imaging biomarkers and incidental dose. The interaction would showcase whether the impact of dose on outcome is dependent on imaging and, hence, if imagi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(11 citation statements)
references
References 48 publications
0
10
1
Order By: Relevance
“…Second, in addition to macroscopic geometric miss, tumor change during the delay may result in a lower and less-uniform dose outside the (true) GTV and underdosage of microscopic disease with the risk of local and distant recurrence. 25 , 26 …”
Section: Discussionmentioning
confidence: 99%
“…Second, in addition to macroscopic geometric miss, tumor change during the delay may result in a lower and less-uniform dose outside the (true) GTV and underdosage of microscopic disease with the risk of local and distant recurrence. 25 , 26 …”
Section: Discussionmentioning
confidence: 99%
“…All patients were staged with both a CT and 18F-FDG positron emission tomography (PET) scan, but did not always receive a histological diagnosis. Four-dimensional computed tomography scans (4D-CT) and three-dimensional dose distributions were available, as described previously and in Supplementary Material (SM), Section 1 ( 19 ). Clinical data was retrospectively collected from structured e-forms completed in routine practice.…”
Section: Methodsmentioning
confidence: 99%
“…The radial histogram framework described in our previous work was implemented to measure density and dose at radial distances from the generated GTV for all patients ( 19 ). A 2D cross-histogram of density vs distance in bins of 1mm annuli from -0.5 to 2cm from the GTV was formed for each 4D phase considering lung tissue only.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations