2010
DOI: 10.1016/j.ijheatmasstransfer.2009.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Radially resolved measurement of stator heat transfer in a rotor–stator disc system

Abstract: This paper describes a new experimental method for measuring stator heat transfer in a rotor-stator disc system using an electrical heater array. The system is partially blocked at the periphery, with radial outflow of rotor-pumped air from an inlet at stator centre. The aim is to improve thermal performance prediction for air-cooled disc type electrical machines. Local Nusselt numbers were measured for 0.6 < r R < 1 at three non-dimensional gap ratios G = g R = (0.0106, 0.0212, 0.0297) and rotational Reynolds… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
11
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(13 citation statements)
references
References 14 publications
2
11
0
Order By: Relevance
“…16,17 . This is up to an order of magnitude higher than in conventional reactors, such as stirred tanks, bubble columns, and packed bed reactors.…”
mentioning
confidence: 99%
“…16,17 . This is up to an order of magnitude higher than in conventional reactors, such as stirred tanks, bubble columns, and packed bed reactors.…”
mentioning
confidence: 99%
“…All the tested correlations available in the literature have proven to be unsuitable. The objective of this research is to obtain reliable and accurate models to calculate the heat transfer coefficient needed for the further design of the optimal cooling system of a hightemperature PEMFC stack that will be incorporated to the powerplant of a light UAV capable of reaching an altitude of 10,000 m. To this end, the energy supply technique [12,13] has been applied in experiments performed in two rectangular tunnels, for three different form factors, in conditions similar to those expected for the HT-PEMFC stack. For calculations, convective and radiative processes are considered.…”
Section: Latin Alphabetmentioning
confidence: 99%
“…An example of this method is the determination of the surface temperature analyzing the emitted radiation intensity and wavelength using infrared cameras [10,11]. A direct heat transfer measurement method is the energy supply technique, in which the temperature of a solid surface is measured while actively providing heat [12,13]. Other methods for the direct measurement of the heat transfer coefficient are the use of thin film heat flux sensors [14e16] or the one based on naphthalene sublimation that has been used to measure the convective heat transfer coefficient on the horizontal roof of a real building [17].…”
Section: Introductionmentioning
confidence: 99%
“…The resultant uncertainty of the open load loss is derived from the first-order approximation of the total error arising from product of torque and rotation speed. The details of the uncertainty analysis will not be presented here but is discussed in [12]. The uncertainty for this set of open load loss measurement has a maximum value of 7.7%.…”
Section: Experimental Measurementmentioning