2011
DOI: 10.1016/j.radmeas.2011.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Radiation characteristics of homemade radiophotoluminescent glass dosimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…Silver-activated metaphosphate glass was produced from reagent-grade powders using a melting method (Lee et al, 2011). NaPO 3 , Al(PO 3 ) 3 and AgCl powders were mixed in a mullite crucible.…”
Section: Methodsmentioning
confidence: 99%
“…Silver-activated metaphosphate glass was produced from reagent-grade powders using a melting method (Lee et al, 2011). NaPO 3 , Al(PO 3 ) 3 and AgCl powders were mixed in a mullite crucible.…”
Section: Methodsmentioning
confidence: 99%
“…However, the elemental composition of these phosphate glasses cannot be modified by users. We therefore fabricated an RPL phosphate glass dosimeter in our laboratory using a conventional method [12,13] , namely, melting industrial-grade powders of sodium metaphosphate (NaPO 3 ) and aluminum metaphosphate (Al(PO 3 ) 3 ) (Taihei Chemical Industrial Co. Ltd.). The powders were homogenized and placed in crucibles.…”
Section: A) Fabrication Of the Radio-photoluminescence Glass Dosimetermentioning
confidence: 99%
“…The evaluated wavelength of the peak was 650 nm. The proton beam irradiation on RPL(Cu) glass was done within an area of 0.55 cm 2 using a beam current of 40 pC/s, with a scanning speed of 0.2 ms/point, which gives a beam fluence of approximately 4×10 12 ions/cm 2 . Evaluation of concrete information about the sensitiveness of RPL(Cu) for the beam irradiation is left for future investigations.…”
Section: B) Comparison Of Rpl Spectra Of X-ray Irradiationmentioning
confidence: 99%
“…A commercially available phosphate glass dosimeter (AGC Techno Glass GD-450) with a silver (Ag + ) activator was supplied by Chiyoda Technol. Note that the elemental composition of their glass cannot be modified according to the user's request, so handmade RPL glass was fabricated by a conventional method, [29][30][31] which involved the melting of industrial-grade powders of sodium metaphosphate (NaPO 3 ) and aluminum metaphosphate [Al(PO 3 ) 3 ] (Taihei Chemical Industrial). Reagent-grade silver chloride (AgCl) and copper chloride (CuCl) were separately added to crucibles and placed in an electric furnace after homogenization of the above powders at the appropriate composition.…”
Section: Preparation Of Rpl Glass Dosimeter For Microdosimetrymentioning
confidence: 99%