Radiation exposure dose and influencing factors during endoscopic retrograde cholangiopancreatography

Abstract: IntroductionVarious endoscopic procedures under fluoroscopic guidance are being rapidly adopted, and radiation exposure is considered to be increasing. However, there is little concern about this issue in gastroenterology practice. This study aims to evaluate the actual radiation exposure dose (RD) during endoscopic retrograde cholangiopancreatography (ERCP) and the factors affecting the RD.MethodsIn this retrospective, single-center cohort study of 1157 consecutive patients who underwent ERCP between October … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(19 citation statements)
references
References 29 publications
0
19
0
Order By: Relevance
“…In addition, separate DRLs must be established for each country and/or region because the equipment and procedure protocols can vary among different regions 25. However, the amount of RE depends on the procedure complexity, patient anatomy, lesion characteristics, disease severity11 and type of fluoroscopic devices20; thus, setting the upper limit of radiation use by applying uniform standards is difficult. Generally, DRLs are not dose limits and do not help distinguish between good and poor medical practices 25.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, separate DRLs must be established for each country and/or region because the equipment and procedure protocols can vary among different regions 25. However, the amount of RE depends on the procedure complexity, patient anatomy, lesion characteristics, disease severity11 and type of fluoroscopic devices20; thus, setting the upper limit of radiation use by applying uniform standards is difficult. Generally, DRLs are not dose limits and do not help distinguish between good and poor medical practices 25.…”
Section: Discussionmentioning
confidence: 99%
“…Clinical factors related to ERCP and interventional EUS have been retrospectively collected at two sites (Toyonaka Municipal Hospital and Kindai University) 20 22–24. We used those published data to develop plans for the design or implementation of this study and to determine the research question or the outcome measures.…”
Section: Methods and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The extent of radiation exposure among medical staff is influenced by various factors, such as the environment of the endoscopy unit, distance between the medical staff and radiation source or patient, type of X-ray system (over-couch, under-couch, or mobile C-arm unit), fluoroscopy parameters (use of pulsed rather than continuous fluoroscopy, use of lower frame rates of fluoroscopy, number of radiographs, use of X-ray beam collimation, or use of low magnification), and use of protective equipment. [ 10 , 21 24 ] Moreover, the fluoroscopy time is influenced by various factors, such as the difficulty of the procedure, [ 25 , 26 ] proficiency levels of the endoscopist and assistant, [ 6 ] education and awareness of radiation protection, [ 27 , 28 ] and number of interventional endoscopic procedures during a specific period. Our institution uses an over-couch X-ray system associated with high radiation exposure at the endoscopist's thyroid gland and eye levels, and the dose might exceed the ICRP limit.…”
Section: Discussionmentioning
confidence: 99%
“…The physical environment of the ERCP unit, the distance between medical staff and the radiation source or the patient, the type of X-ray system (over-couch, under-couch, or mobile C-arm unit), the fluoroscopy parameters (use of pulsed rather than continuous fluoroscopy, use of lower frame rates of fluoroscopy, number of radiographs, use of collimation of X-ray beam, use of low magnification) and the use of protective equipment can affect the radiation dose 6 16–19. Moreover, the fluoroscopy time is determined by important factors such as the difficulty of the procedure,20 21 the proficiency level of the endoscopist and the assistant,22 education and awareness regarding radiation protection,23 24 and the number of ERCP procedures during the period. Hence, the different scenarios at each institution and those of the ERCP units should be taken into account when comparing the degree of radiation exposure for each institution.…”
Section: Discussionmentioning