Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background Radiation pneumonitis (RP) is one of the common side effects after adjuvant radiotherapy in breast cancer. Irradiation dose to normal lung was related to RP. We aimed to propose an organ features based on deep learning (DL) model and to evaluate the correlation between normal lung dose and organ features. Methods Patients with pathology-confirmed invasive breast cancer treated with adjuvant radiotherapy following breast-conserving surgery in four centers were included. From 2019 to 2020, a total of 230 patients from four nationwide centers in China were screened, of whom 208 were enrolled for DL modeling, and 22 patients from another three centers formed the external testing cohort. The subset of the internal testing cohort (n = 42) formed the internal correlation testing cohort for correlation analysis. The outline of the ipsilateral breast was marked with a lead wire before the scanning. Then, a DL model based on the High-Resolution Net was developed to detect the lead wire marker in each slice of the CT images automatically, and an in-house model was applied to segment the ipsilateral lung region. The mean and standard deviation of the distance error, the average precision, and average recall were used to measure the performance of the lead wire marker detection model. Based on these DL model results, we proposed an organ feature, and the Pearson correlation coefficient was calculated between the proposed organ feature and ipsilateral lung volume receiving 20 Gray (Gy) or more (V20). Results For the lead wire marker detection model, the mean and standard deviation of the distance error, AP (5 mm) and AR (5 mm) reached 3.415 ± 4.529, 0.860, 0.883, and 4.189 ± 8.390, 0.848, 0.830 in the internal testing cohort and external testing cohort, respectively. The proposed organ feature calculated from the detected marker correlated with ipsilateral lung V20 (Pearson correlation coefficient, 0.542 with p < 0.001 in the internal correlation testing cohort and 0.554 with p = 0.008 in the external testing cohort). Conclusions The proposed artificial Intelligence-based CT organ feature was correlated with normal lung dose in adjuvant radiotherapy following breast-conserving surgery in patients with invasive breast cancer. Trial registration NCT05609058 (08/11/2022).
Background Radiation pneumonitis (RP) is one of the common side effects after adjuvant radiotherapy in breast cancer. Irradiation dose to normal lung was related to RP. We aimed to propose an organ features based on deep learning (DL) model and to evaluate the correlation between normal lung dose and organ features. Methods Patients with pathology-confirmed invasive breast cancer treated with adjuvant radiotherapy following breast-conserving surgery in four centers were included. From 2019 to 2020, a total of 230 patients from four nationwide centers in China were screened, of whom 208 were enrolled for DL modeling, and 22 patients from another three centers formed the external testing cohort. The subset of the internal testing cohort (n = 42) formed the internal correlation testing cohort for correlation analysis. The outline of the ipsilateral breast was marked with a lead wire before the scanning. Then, a DL model based on the High-Resolution Net was developed to detect the lead wire marker in each slice of the CT images automatically, and an in-house model was applied to segment the ipsilateral lung region. The mean and standard deviation of the distance error, the average precision, and average recall were used to measure the performance of the lead wire marker detection model. Based on these DL model results, we proposed an organ feature, and the Pearson correlation coefficient was calculated between the proposed organ feature and ipsilateral lung volume receiving 20 Gray (Gy) or more (V20). Results For the lead wire marker detection model, the mean and standard deviation of the distance error, AP (5 mm) and AR (5 mm) reached 3.415 ± 4.529, 0.860, 0.883, and 4.189 ± 8.390, 0.848, 0.830 in the internal testing cohort and external testing cohort, respectively. The proposed organ feature calculated from the detected marker correlated with ipsilateral lung V20 (Pearson correlation coefficient, 0.542 with p < 0.001 in the internal correlation testing cohort and 0.554 with p = 0.008 in the external testing cohort). Conclusions The proposed artificial Intelligence-based CT organ feature was correlated with normal lung dose in adjuvant radiotherapy following breast-conserving surgery in patients with invasive breast cancer. Trial registration NCT05609058 (08/11/2022).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.