2020
DOI: 10.1016/j.radphyschem.2020.108781
|View full text |Cite
|
Sign up to set email alerts
|

Radiation safety assessment of caregivers of thyroid cancer patients treated with 131I in Taiwan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0
3

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 2 publications
0
4
0
3
Order By: Relevance
“…3 Chen et al (2020) reported that radiation dose of caregivers was ≤5 mSv or the dose rate was ≤50 µSv/h at a 1-meter distance from the patients when patients were administered radiodine-131 therapy. 10…”
Section: Health Impacts Of Very Low-dose Ionizing Radiationmentioning
confidence: 99%
See 1 more Smart Citation
“…3 Chen et al (2020) reported that radiation dose of caregivers was ≤5 mSv or the dose rate was ≤50 µSv/h at a 1-meter distance from the patients when patients were administered radiodine-131 therapy. 10…”
Section: Health Impacts Of Very Low-dose Ionizing Radiationmentioning
confidence: 99%
“…D, MD, Mr. Mark L. Miller and Dr. Mohan Doss, certified Medical/Health Physicists et al (petitions submitted in 2015 for rulemaking to discontinue use of the LNT model) due to inadequate data supporting the request. 15 Such a result indicates that more convincing data 8–10 or conceptual illustration 11 is necessary.…”
Section: Beyond the Linear No-threshold Theorymentioning
confidence: 99%
“…Variáveis: Todas as variáveis envolvidas somadas à ampla gama de atividades de NaI-131 administrada precisam ser consideradas e dificultam muito no momento de definir as orientações de Proteção Radiológica (PRT), sendo assim aplicar um padrão se torna uma alternativa inapropriada 22 . Devido às variáveis de retenção e metabolismo do iodo há grande dificuldade em estimar a taxa de dose emitida pelo paciente no ambiente 8 . Em acompanhamento periódico a pacientes de CT e HT por 21 dias Mathieu et al 16 constatou dose média de 0,5 mSv para os parceiros e para as crianças e meia-vida efetiva média 2,2 dias para os pacientes CT, meia vida de 6,2 dias e mediana de 1,04 mSv para parceiros e crianças de pacientes HT.…”
Section: Pant Et Alunclassified
“…. Inexistência de diretrizes: A preocupação dos efeitos da radiação no ambiente e membros do público é relativamente recente, muitos países não possuem nenhuma legislação que limite a dose que pode ser administrada de modo ambulatorial, Chen et al 8 declara com preocupação que em alguns países não existem limites de dose para pacientes submetidos à radioiodoterapia.…”
unclassified
See 1 more Smart Citation