Radiation Therapy with Implanted Cardiac Pacemaker Devices: a Clinical and Dosimetric Analysis of Patients and Proposed Precautions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
54
0
2

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(56 citation statements)
references
References 11 publications
0
54
0
2
Order By: Relevance
“…In the same paper, they reported that they did not find any defects during an in vitro study of 20 ICDs irradiated to a dose of 4 Gy. Wadasadawala et al reported on 8 pacemaker patients receiving a cumulative dose of 0.14-60 Gy to the pacemaker and found no defects with a median follow-up of 5 months [3]. Gelblum et al reported on 33 patients with an ICD, with dose to ICD ranging from 1 cGy to 300 cGy [37].…”
Section: Methodsmentioning
confidence: 99%
“…In the same paper, they reported that they did not find any defects during an in vitro study of 20 ICDs irradiated to a dose of 4 Gy. Wadasadawala et al reported on 8 pacemaker patients receiving a cumulative dose of 0.14-60 Gy to the pacemaker and found no defects with a median follow-up of 5 months [3]. Gelblum et al reported on 33 patients with an ICD, with dose to ICD ranging from 1 cGy to 300 cGy [37].…”
Section: Methodsmentioning
confidence: 99%
“…Cardiac implantable electronic devices are composed of, and can be contoured into, many different sections . The electronically sensitive component of the device is the body.…”
Section: Patient Management and Recommendationsmentioning
confidence: 99%
“…9799 Exposure to therapeutic radiation has been associated with pacing inhibition, inappropriate tracking, noise-reversion, inappropriate shocks, CIEDs failure, and runaway pacing with induction of potentially life-threatening ventricular arrhythmias. 73, 74, 100 The cumulative effect of ionizing radiation on the oxide layers of CMOS circuits utilized in CIEDs 75 vary depending on the type (photon vs. proton based therapy), dose measured as energy absorbed per mass with units of joule per kilogram or gray (Gy), direction of radiation, and device type and location. 101, 102 A dose range as wide as 0.5 to 120 Gy could be associated with ICD failure.…”
Section: Radiotherapy and Ionizing Radiationmentioning
confidence: 99%