OBJECTIVE: To cure atrial fibrillation, the maximum ablation depth (⩾ 50∘C) should exceed the myocardial thickness to achieve the effect of transmural ablation. The blood flow of pulmonary vein in the endocardium can cause the change in the myocardial temperature distribution. Therefore, the study investigated the effect of different pulmonary vein blood flow velocities on the endocardial microwave ablation. METHODS: The finite element model of the endocardial microwave ablation of pulmonary vein was simulated by electromagnetic thermal flow coupling. The ablation power was 30 W and the ablation time was within 30 s. The blood flow in the coupling of fluid mechanics equation and heat transfer equation results in the heat damage. Furthermore, the cause of the different lesion dimensions is the blood flow velocity. The flow velocities were set as 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s. RESULTS: When the flow velocities were 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s, the maximum ablation depth were 6.0, 5.56, 5.16, 5.12, 5.04, 5.01, 4.98, 4.96 and 4.94 mm, respectively; the maximum ablation width were 12.52, 9.63, 9.23, 9.16, 9.07, 9.05, 8.94, 8.91, 8.90 mm, respectively; the maximum ablation length were 12.00, 11.61, 8.98, 8.59, 8.37, 8.23, 8.16, 8.06 and 8.04 mm respectively. To achieve transmural ablation, the time was 3, 3, 3, 3, 3, 4, 4, 4, 4 s, respectively when the myocardial thickness was 2 mm; the time was 7, 8, 8, 8, 9, 9, 9, 9, 9 s, respectively when 3 mm; the time was 15, 16, 18, 19, 19, 20, 20, 20, 20 s, respectively when 4 mm. CONCLUSIONS: When the velocity increases from 0 m/s to 3 m/s, the microwave lesion depth decreases by 1.06 mm. To achieve transmural ablation, when the myocardial thickness is 2 mm, 3 and 4 s should be taken when the velocity is 0–0.12 and 0.120.30 m/s, respectively; when the myocardial thickness is 3 mm, 7, 8 and 9 s should be taken when 0, 0–0.07 and 0.07–0.30 m/s respectively; when the myocardial thickness is 4 mm, 15, 16, 18, 19, 20 s should be taken when 0, 0–0.02, 0.02–0.05, 0.05–0.12, 0.12 m/s–0.30 m/s.
OBJECTIVE: To cure atrial fibrillation, the maximum ablation depth (⩾ 50∘C) should exceed the myocardial thickness to achieve the effect of transmural ablation. The blood flow of pulmonary vein in the endocardium can cause the change in the myocardial temperature distribution. Therefore, the study investigated the effect of different pulmonary vein blood flow velocities on the endocardial microwave ablation. METHODS: The finite element model of the endocardial microwave ablation of pulmonary vein was simulated by electromagnetic thermal flow coupling. The ablation power was 30 W and the ablation time was within 30 s. The blood flow in the coupling of fluid mechanics equation and heat transfer equation results in the heat damage. Furthermore, the cause of the different lesion dimensions is the blood flow velocity. The flow velocities were set as 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s. RESULTS: When the flow velocities were 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s, the maximum ablation depth were 6.0, 5.56, 5.16, 5.12, 5.04, 5.01, 4.98, 4.96 and 4.94 mm, respectively; the maximum ablation width were 12.52, 9.63, 9.23, 9.16, 9.07, 9.05, 8.94, 8.91, 8.90 mm, respectively; the maximum ablation length were 12.00, 11.61, 8.98, 8.59, 8.37, 8.23, 8.16, 8.06 and 8.04 mm respectively. To achieve transmural ablation, the time was 3, 3, 3, 3, 3, 4, 4, 4, 4 s, respectively when the myocardial thickness was 2 mm; the time was 7, 8, 8, 8, 9, 9, 9, 9, 9 s, respectively when 3 mm; the time was 15, 16, 18, 19, 19, 20, 20, 20, 20 s, respectively when 4 mm. CONCLUSIONS: When the velocity increases from 0 m/s to 3 m/s, the microwave lesion depth decreases by 1.06 mm. To achieve transmural ablation, when the myocardial thickness is 2 mm, 3 and 4 s should be taken when the velocity is 0–0.12 and 0.120.30 m/s, respectively; when the myocardial thickness is 3 mm, 7, 8 and 9 s should be taken when 0, 0–0.07 and 0.07–0.30 m/s respectively; when the myocardial thickness is 4 mm, 15, 16, 18, 19, 20 s should be taken when 0, 0–0.02, 0.02–0.05, 0.05–0.12, 0.12 m/s–0.30 m/s.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.