Radio‐guided and clip‐guided preoperative localization for malignant microcalcifications offer similar performances in breast‐conserving surgery

Abstract: Obtaining a tailored breast resection is challenging in microcalcifications detected on screening mammography, and an accurate localization is required. The aim of this study was to compare the efficacy of radio‐guided localization (ROLL) versus ultrasound localization of a titanium clip with collagen (TCC) in terms of clear margins, re‐intervention rates, excess of resected breast tissue, and operative times in pure malignant microcalcifications detected on screening mammography. Two hundred and twenty‐one co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 42 publications
0
6
0
Order By: Relevance
“…However, these techniques are limited by radiation exposure, poor initial seed placement, seed displacement, depth limitation, and high cost. Additionally, there is a limitation related to the difficulty of marking the extent of breast tumors, as depicted by imaging 10,[13][14][15][16][17][18][19][20][21][22][23][24] (Table 4). MRI defines the tumor extent more accurately than other imaging modalities, and it is known to accurately detect multifocal or multicentric cancers 25 .…”
Section: Discussionmentioning
confidence: 99%
“…However, these techniques are limited by radiation exposure, poor initial seed placement, seed displacement, depth limitation, and high cost. Additionally, there is a limitation related to the difficulty of marking the extent of breast tumors, as depicted by imaging 10,[13][14][15][16][17][18][19][20][21][22][23][24] (Table 4). MRI defines the tumor extent more accurately than other imaging modalities, and it is known to accurately detect multifocal or multicentric cancers 25 .…”
Section: Discussionmentioning
confidence: 99%
“…US-guided clip placement has been reported to be more accurate than X-ray-guided placement. [ 3 , 12 ] The expert panel preferred US-guided clip placement, with X-ray-guided placement as an optional method. Regarding the number of clips to be placed, which should balance localization accuracy and medical cost, [ 10 , 11 ] the expert panel recommended one clip for each primary breast lesion or metastatic axillary LN.…”
Section: Discussionmentioning
confidence: 99%
“…US-guided clip placement has been reported to be more accurate than X-ray-guided placement [3,12] . The expert panel preferred US-guided clip placement, with X-ray-guided placement as an optional method.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations