2015
DOI: 10.1016/j.jenvrad.2014.07.026
|View full text |Cite
|
Sign up to set email alerts
|

Radioactive contamination mapping of northeastern and eastern Japan by a car-borne survey system, Radi-Probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
19
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
1
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 14 publications
0
19
0
1
Order By: Relevance
“…Both systems have been used in several projects to establish radiation dose rate maps by the Fukushima Prefectural Government and the Ministry of Education, Culture, Sports, Science and Technology of Japan. Radi-Probe [3], a system developed by the National Institute of Radiological Sciences, uses a HPGe detector and CsI(Tl) detector. Radi-Probe is capable of measuring energy spectra with good energy resolution, the surface deposition density of radionuclides, and the air dose rate.…”
Section: Comparison Of Measured Bishamon Data With Those Of Other Sysmentioning
confidence: 99%
See 1 more Smart Citation
“…Both systems have been used in several projects to establish radiation dose rate maps by the Fukushima Prefectural Government and the Ministry of Education, Culture, Sports, Science and Technology of Japan. Radi-Probe [3], a system developed by the National Institute of Radiological Sciences, uses a HPGe detector and CsI(Tl) detector. Radi-Probe is capable of measuring energy spectra with good energy resolution, the surface deposition density of radionuclides, and the air dose rate.…”
Section: Comparison Of Measured Bishamon Data With Those Of Other Sysmentioning
confidence: 99%
“…Using vehicle-mounted and on-foot survey methods, BISHAMON concurrently measures the ambient dose equivalent rates along with precise geographic coordinates, allowing for the creation of maps that inform on the presence of radiation in the affected communities. In this study, we give an overview of BISHAMON and its measurement results including a comparison with the results of KURAMA [1,2], Radi-Probe [3], and Safecast [4].…”
Section: Introductionmentioning
confidence: 99%
“…Pembuatan SOP untuk penanganan bahaya radiasi sebagai persyaratan bekerja pada zona daerah radiasi dengan membuat beberapa SOP antara lain: SOP pelarutan, SOP transfer, SOP pemisahan isotop 137 Cs di dalam PEB U3Si2-Al pasca iradiasi dan SOP proses proses loading padatan 137 Cszeolit ke dalam inner capsule stainless steel [13] [12] .…”
Section: A Pembuatan Standar Operasi Prosedur (Sop)unclassified
“…4 and Table 2). The 134 Cs/ 137 Cs ratio released from the FNPP1 is known to be approximately 1 (Komori et al, 2013;Kobayashi et al, 2015Kobayashi et al, , 2017. The 134 Cs/ 137 Cs ratios in the upper 9 cm depth of core 4W-2012 range from 0.85 to 1.12 (average; 0.95) ( Fig.…”
mentioning
confidence: 99%