2020
DOI: 10.1017/rdc.2020.102
|View full text |Cite
|
Sign up to set email alerts
|

Radiocarbon in Dissolved Organic Carbon by Uv Oxidation: Procedures and Blank Characterization at Nosams

Abstract: This study describes a procedural blank assessment of the ultraviolet photochemical oxidation (UV oxidation) method that is used to measure carbon isotopes of dissolved organic carbon (DOC) at the National Ocean Sciences Accelerator Mass Spectrometry Facility (NOSAMS). A retrospective compilation of Fm and δ13C results for secondary standards (OX-II, glycine) between 2009 and 2018 indicated that a revised blank correction was required to bring results in line with accepted values. The application of a best-fit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
23
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 25 publications
1
23
0
Order By: Relevance
“…The method is basically the same as that in Xu et al (2021) with several procedural changes. The most notable change relates to handling and exposure of the water-cooling probe: After the UV pretreatment of Milli-Q water (for standards, blanks, and small volume samples), the water-cooling probe is now placed in a cylindrical glass container with 65/40 socket filled with fresh Milli-Q water (Figure 1, right).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The method is basically the same as that in Xu et al (2021) with several procedural changes. The most notable change relates to handling and exposure of the water-cooling probe: After the UV pretreatment of Milli-Q water (for standards, blanks, and small volume samples), the water-cooling probe is now placed in a cylindrical glass container with 65/40 socket filled with fresh Milli-Q water (Figure 1, right).…”
Section: Methodsmentioning
confidence: 99%
“…Another procedural modification, compared to the Xu et al (2021) paper: the halogen trap, previously using a potassium iodine solution, was replaced with a copper wool flow-through Figure 1 The DOC water-cooling probe used at NOSAMS. At left, the water-cooling probe is exposed to air.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Results have been revised based on the recent NOSAMS 14 C-DOC procedural blank correction assessment (Xu et al 2021). Analytical precision for NOSAMS DOC and DIC 14 C Fraction modern (Fm) values was better than 0.005, and for ETH DOC 14 C was better than 0.04.…”
Section: C and 14 C Analyses Of Doc And Dicmentioning
confidence: 99%