2017
DOI: 10.1016/j.radphyschem.2017.02.032
|View full text |Cite
|
Sign up to set email alerts
|

Radiochromic film calibration for the RQT9 quality beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…The absorbed dose values are obtained from the pixel intensity values using calibration curves for each voltage value to get air kerma values [10]. The conversion factors used to determine the dose profile for each protocol in the anthropomorphic phantoms.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The absorbed dose values are obtained from the pixel intensity values using calibration curves for each voltage value to get air kerma values [10]. The conversion factors used to determine the dose profile for each protocol in the anthropomorphic phantoms.…”
Section: Methodsmentioning
confidence: 99%
“…The radiochromic films are calibrated for different energy intensities separately, due to their energy dependence. Studies carries out with PMMA cylindrical head phantom and ionization chambers determined the calibration curves for radiochromic films GAFCHROMIC XR-AQ2 for different voltages of CT X-ray tube [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…for each voltage level, and corrected by the width of the X-ray beam, were calculated values of absorbed dose deposited in each of the strips [11,12].…”
Section: Gafchromic Xr-qa2 Filmmentioning
confidence: 99%
“…Among the methods used for dose measurement in clinical practice, radiochromic films are commonly used in radiation therapy for dosimetric verification of treatment plans, [5][6][7]8 whereas in interventional radiology, they are used to assess the surface dose on the patient's skin(peak skin dose). 3,9 This kind of film is also used for instance to improve CT acquisition image processes 10 and to check the distributions of the laser-accelerated proton beams. 11 Since this dosimetric method is a relative one, the proper calibration curve needs to be determined prior to its use for dose assessment.…”
Section: Introductionmentioning
confidence: 99%
“…11 Since this dosimetric method is a relative one, the proper calibration curve needs to be determined prior to its use for dose assessment. 2,3,4,[10][11][12][13][14] In the literature there is still an insufficient number of detailed descriptions of the calibration curve fitting analysis for XR-RV3 films. Due to the relatively low dose rate of ionizing radiation of X-ray units used in interventional radiology compared to radiotherapeutic units, this process performed in clinical conditions is somewhat time-consuming.…”
Section: Introductionmentioning
confidence: 99%