2003
DOI: 10.1007/s00330-002-1809-0
|View full text |Cite
|
Sign up to set email alerts
|

Radiogenic risks from hysterosalpingography

Abstract: The aim of this study was to determine ovarian dose, effective dose and associated radiogenic risks from hysterosalpingography (HSG), and to provide data for the estimation of radiogenic risks related to HSG studies performed in any laboratory. The fluoroscopy time, number of radiographs taken and entrance surface dose were measured in a series of 78 consecutive patients undergoing HSG as part of their infertility work-up. Organ-dose values per radiograph and per minute of fluoroscopy were separately determine… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
23
1
11

Year Published

2008
2008
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(37 citation statements)
references
References 16 publications
2
23
1
11
Order By: Relevance
“…[8] Careful analysis of the working procedures and clinical protocols generally used in radiological practise, to avoid unnecessary exposures with no loss in diagnostic information, is required. [9]…”
Section: Introductionmentioning
confidence: 99%
“…[8] Careful analysis of the working procedures and clinical protocols generally used in radiological practise, to avoid unnecessary exposures with no loss in diagnostic information, is required. [9]…”
Section: Introductionmentioning
confidence: 99%
“…There have been a number of dosimetric studies evaluating gonadal radiation exposure during hysterosalpingograms (3,4,9,10). Each reports slightly different values as technologies have improved and protocols differ by institution with varying fluoroscopy times and number of radiographs obtained.…”
Section: Discussionmentioning
confidence: 98%
“…Changes in HSG protocols intended to limit the number of exposures, such as elimination of the routine oblique and lateral radiographic projections, have reduced radiation exposure (9). The use of digital fluoroscopy for HSG has been shown to reduce patient radiation exposure compared with analogue fluoroscopy (4).…”
Section: Discussionmentioning
confidence: 99%
“…Dose to the female gonads from an average hysterosalpingographic procedure has been found to be low (1.2 mSv) [3], but risks to the embryo due to the mechanical trauma of the contrast material injection are uncertain. Spontaneous abortions after HSG have been reported [4], although whether such abortions were caused by HSG or were coincidental is difficult to determine given the small number of reported cases.…”
Section: Introductionmentioning
confidence: 99%