2001
DOI: 10.1053/jvet.2001.20343
|View full text |Cite
|
Sign up to set email alerts
|

Radiographic Evaluation of Acetabular Component Position in Dogs

Abstract: Computer-aided image analysis can be used to calculate angles of lateral opening to within 10 degrees throughout the range of acetabular positions seen in practice and is appropriate for postoperative documentation of cup position. The angles of inclination and version should be interpreted with caution.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
79
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 41 publications
(82 citation statements)
references
References 10 publications
3
79
0
Order By: Relevance
“…The inclusion of both cemented and cementless THR in this study implies the use of different techniques to measure ALO. The ellipse and Renwick methods for ALO measurement have a reported accuracy of 5 °‐10 °; however, their accuracy decreases with increasing IA, pelvic rotation, and decreasing ALO . The accuracy of VA measurement is affected by declining ALO, cup size, and IA .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The inclusion of both cemented and cementless THR in this study implies the use of different techniques to measure ALO. The ellipse and Renwick methods for ALO measurement have a reported accuracy of 5 °‐10 °; however, their accuracy decreases with increasing IA, pelvic rotation, and decreasing ALO . The accuracy of VA measurement is affected by declining ALO, cup size, and IA .…”
Section: Discussionmentioning
confidence: 99%
“…For cemented THR cases, the ALO was calculated by using the ellipse of best‐fit method (Figure ) . For uncemented THR cases, the ALO for size 24‐, 28‐, and 32‐mm cups was measured by using a system described by Renwick et al If a size 20‐, 26‐, or 30‐mm cup was used, the ALO was estimated from the available data .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…12 In each radiographic image, the NA of the hip joint was measured 3 times by each of 2 operators (designated as OP-A and OP-B), who were unaware of the extent and direction of pelvic tilt. 12 In each radiographic image, the NA of the hip joint was measured 3 times by each of 2 operators (designated as OP-A and OP-B), who were unaware of the extent and direction of pelvic tilt.…”
Section: Methodsmentioning
confidence: 99%
“…In one smaller patient and two where remodelling of the acetabulum had occurred, acetabular bone stock was felt to be insufficient to support a cementless cup and cemented fixation was employed. Assessment of implant orientation has been previously described in detail (Dyce and others , Renwick and others ). Postoperative radiographs showed satisfactory implant orientation in all cases in this study.…”
Section: Discussionmentioning
confidence: 99%