2020
DOI: 10.1080/03067319.2020.1849658
|View full text |Cite
|
Sign up to set email alerts
|

Radiological safety assessment of mined Trona commonly consumed in Nigeria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…The detector consists of a 7.62 × 7.62 cm NaI (TI) detector housed in a 10 cm thick lead-shield, cadmium-lined assembly with copper sheets for the reduction of background radiation, which was equipped with a MAESTRO computer system program for data acquisition and spectra analysis. IAEA standard reference materials (RGK-1, IAEA-448, and RGTh-1) were used for the quantitative analysis of the 238 U, 232 Th, and 40 K, respectively 5 , 20 . Each of the prepared samples was counted for approximately 4 h, with the activity concentration of 238 U determined using the gamma energy line of 214 Bi (1760 keV), 232 Th determined using 208 Tl (2614 keV), while the activity concentration of 40 K was determined directly from its 1460 keV gamma line.…”
Section: Methodsmentioning
confidence: 99%
“…The detector consists of a 7.62 × 7.62 cm NaI (TI) detector housed in a 10 cm thick lead-shield, cadmium-lined assembly with copper sheets for the reduction of background radiation, which was equipped with a MAESTRO computer system program for data acquisition and spectra analysis. IAEA standard reference materials (RGK-1, IAEA-448, and RGTh-1) were used for the quantitative analysis of the 238 U, 232 Th, and 40 K, respectively 5 , 20 . Each of the prepared samples was counted for approximately 4 h, with the activity concentration of 238 U determined using the gamma energy line of 214 Bi (1760 keV), 232 Th determined using 208 Tl (2614 keV), while the activity concentration of 40 K was determined directly from its 1460 keV gamma line.…”
Section: Methodsmentioning
confidence: 99%
“…The detector consist of a 7.62 × 7.62 cm NaI (Tl) detector housed in a 10 cm thick lead-shielded, cadmium-lined assembly with copper sheets for the reduction of background radiation, which was equipped with a MAESTRO computer system program for data acquisition and spectra analysis. IAEA standard reference materials (RGK-1, IAEA-448 and RGTh-1) were used for the quantitative analysis of the 226 Ra, 232 Th, and 40 K respectively [ 30 ]. Each of the prepared sample was counted for approximately 8 h with the activity concentration of 226 Ra determined using the gamma energy line of 214 Bi (1760 keV), 232 Th using 208 Tl (2614 keV), and while the activity concentration of 40 K was determined directly from its 1460 keV gamma line.…”
Section: Methodsmentioning
confidence: 99%