2023
DOI: 10.3390/bios13060609
|View full text |Cite
|
Sign up to set email alerts
|

Raman Spectroscopy for Urea Breath Test

Abstract: The urea breath test is a non-invasive diagnostic method for Helicobacter pylori infections, which relies on the change in the proportion of 13CO2 in exhaled air. Nondispersive infrared sensors are commonly used for the urea breath test in laboratory equipment, but Raman spectroscopy demonstrated potential for more accurate measurements. The accuracy of the Helicobacter pylori detection via the urea breath test using 13CO2 as a biomarker is affected by measurement errors, including equipment error and δ13C mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 41 publications
0
1
0
Order By: Relevance
“…Matrix effects are inherent to sample properties, such as pH or scattering effects, affecting the proportions of Mie and Rayleigh scattering and absorbance bands [4,5]. Clinical and analytical chemistry address spectral interference through sample composition simplification (e.g., separation using filtration, centrifugation, chromatography) or reaction specificity on biochips (e.g., immunological reactions, molecularly imprinted polimers, aptamers), not taking advantage of the rich information present in spectra [6][7][8][9][10]. Unscrambling the multi-scaled interference and matrix effects, and unlocking constituent-specific information in each spectrum, lies at the heart of reagentless POC technology [1,11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Matrix effects are inherent to sample properties, such as pH or scattering effects, affecting the proportions of Mie and Rayleigh scattering and absorbance bands [4,5]. Clinical and analytical chemistry address spectral interference through sample composition simplification (e.g., separation using filtration, centrifugation, chromatography) or reaction specificity on biochips (e.g., immunological reactions, molecularly imprinted polimers, aptamers), not taking advantage of the rich information present in spectra [6][7][8][9][10]. Unscrambling the multi-scaled interference and matrix effects, and unlocking constituent-specific information in each spectrum, lies at the heart of reagentless POC technology [1,11,12].…”
Section: Introductionmentioning
confidence: 99%