2020
DOI: 10.1089/dia.2020.0022
|View full text |Cite
|
Sign up to set email alerts
|

Randomized Crossover Comparison of Automated Insulin Delivery Versus Conventional Therapy Using an Unlocked Smartphone with Scheduled Pasta and Rice Meal Challenges in the Outpatient Setting

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 34 publications
0
5
0
Order By: Relevance
“…Commercially available AID systems are hybrid closed-loop systems, and they require these manual entries by the user. AID systems, also called artificial pancreas (AP), consist of a CGM, an insulin pump, and a closed-loop control algorithm that manipulates the insulin infusion rate delivered by the pump based on the recent CGM values reported [10][11][12][13][14][15][16][17][18][19][20][21][22][23]. More advanced AID systems that use a multivariable approach [10,[24][25][26] use additional inputs from wearable devices (such as wristbands) to automatically detect the occurrence of physical activity and incorporate this information to the automated control algorithms for a fully automated AID system [27].…”
Section: Introductionmentioning
confidence: 99%
“…Commercially available AID systems are hybrid closed-loop systems, and they require these manual entries by the user. AID systems, also called artificial pancreas (AP), consist of a CGM, an insulin pump, and a closed-loop control algorithm that manipulates the insulin infusion rate delivered by the pump based on the recent CGM values reported [10][11][12][13][14][15][16][17][18][19][20][21][22][23]. More advanced AID systems that use a multivariable approach [10,[24][25][26] use additional inputs from wearable devices (such as wristbands) to automatically detect the occurrence of physical activity and incorporate this information to the automated control algorithms for a fully automated AID system [27].…”
Section: Introductionmentioning
confidence: 99%
“…Baseline: The standard zone-MPC that is tuned for and has been successfully tested on non-pregnant individuals. The values in ψ Baseline are available in ( 17 ) and ( 21 ).…”
Section: Resultsmentioning
confidence: 99%
“…We present the mathematical details of the parts of zone-MPC that we tailor for use during pregnancy. Other details are presented at a higher level and the interested reader is referred to ( 15 , 16 ), and ( 17 ) for further technical information, and to ( 18 21 ) for previous clinical trials that demonstrated safety and efficacy of the zone-MPC algorithm in adults and adolescents with T1D.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Automated insulin delivery and CL systems were shown to provide a significant improvement in HbA1c values, a significant reduction in hypoglycemia and hyperglycemia or increased TIR, and an improvement in the quality of life and sleep [ 28 30 ]. Lewis et al achieved similar results in a retrospective crossover analysis of 20 participants for measurements 4 to 6 weeks before using the OpenAPS system and after 4 to 6 weeks of using the system [ 31 ].…”
Section: Discussionmentioning
confidence: 99%