Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized 3He with Flip angle variation for offset of RF and relaxation (FAVOR)

Abstract: A novel imaging method is presented, Flip Angle Variation for Offset of RF and Relaxation (FAVOR), for rapid and efficient measurement of rat lung ventilation using hyperpolarized helium-3 ( 3 He) gas. The FAVOR technique utilizes variable flip angles to remove the cumulative effect of RF pulses and T 1 relaxation on the hyperpolarized gas signal and thereby eliminates the need for intervening air wash-out breaths and multiple cycles of 3 He wash-in breaths before each image. The former allows an improvement i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
67
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 44 publications
(70 citation statements)
references
References 18 publications
3
67
0
Order By: Relevance
“…The RF pulse flip angle was varied throughout the k-space acquisition as described by Zhao et al to compensate for gas depolarization due to RF pulse history (32,33) and TR, TE and b were small compared to T 1, T 2 Ã and ADC respectively (as described below) such that the resulting MR image signal strength (Eq. [1]) was weighted only by the density of 3 He gas, thus permitting measurement of absolute lung volume for comparison with micro-CT.…”
Section: Animal Preparationmentioning
confidence: 99%
“…The RF pulse flip angle was varied throughout the k-space acquisition as described by Zhao et al to compensate for gas depolarization due to RF pulse history (32,33) and TR, TE and b were small compared to T 1, T 2 Ã and ADC respectively (as described below) such that the resulting MR image signal strength (Eq. [1]) was weighted only by the density of 3 He gas, thus permitting measurement of absolute lung volume for comparison with micro-CT.…”
Section: Animal Preparationmentioning
confidence: 99%
“…129 Xe and 3 He lung imaging was performed in five Sprague Dawley rats (500 6 25 mg, Charles River Laboratories, Saint-Constant, Canada) ventilated with a custom-built ventilation system using a University-approved animal care protocol described previously (29,30). Imaging was performed during a 7 s breath-hold interval following eight wash-out breaths with either hyperpolarized 129 Xe or 3 He gas.…”
Section: Mr Methodsmentioning
confidence: 99%
“…The ET tube was then attached directly to a small animal custom ventilator (GEHC, Malmo, Sweden) compatible with HNG MRI. 15 Insertion of the Foley catheter required no surgery. The Foley cuff was inflated using the assembly shown in Figure 1.…”
Section: Animalsmentioning
confidence: 99%
“…The SNR measured is comparable with other 2D images acquired using the standard method after a single breath of 3 He with an SNR of 185. 15 …”
Section: Quality Of Breath-holdmentioning
confidence: 99%