2023
DOI: 10.1016/j.scitotenv.2022.159427
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and sensitive detection of quizalofop-p-ethyl by gold nanoparticle-based lateral flow immunoassay in agriproducts and environmental samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…The concentrations of mAbs and antigens are important for the sensitivity of the CLFIA [29,30]. In our study, AuNP-mAb (1 to 6 µL) and coating antigen (0.075 to 1.2 mg mL −1 ) were used to detect pyridaben standard (0 to 80 ng mL −1 ) in PBS, with 0.1 mg mL −1 goat anti-mouse IgG fixed on the C-line.…”
Section: Clfia Optimizationmentioning
confidence: 99%
“…The concentrations of mAbs and antigens are important for the sensitivity of the CLFIA [29,30]. In our study, AuNP-mAb (1 to 6 µL) and coating antigen (0.075 to 1.2 mg mL −1 ) were used to detect pyridaben standard (0 to 80 ng mL −1 ) in PBS, with 0.1 mg mL −1 goat anti-mouse IgG fixed on the C-line.…”
Section: Clfia Optimizationmentioning
confidence: 99%
“…The results indicated a detection limit of 0.16 mg/kg in banana. However, the long reaction time, tedious operating procedures, and the need for specialized equipment have limited the application of ELISAs in field testing ( 18 ).…”
Section: Introductionmentioning
confidence: 99%
“…To date, indirect competitive ELISAs (ic-ELISAs) on the basis of anti-CAP monoclonal antibody (mAb) for CAP detection in environmental and agricultural samples have shown half-inhibitory concentrations (IC 50 ) of 1.6 ng/mL [18] and 1.5 ng/mL [19]. However, the long reaction time, tedious operating procedures, and the need for specialized equipment have limited the application of ELISAs in field testing [20]. Compared with ELISAs, gold nanoparticle-based lateral flow immunoassays (AuNP-LFIAs) possess the advantages of one-step detection and do not require specialized equipment and direct visual readout [17].…”
Section: Introductionmentioning
confidence: 99%
“…Compared with ELISAs, gold nanoparticle-based lateral flow immunoassays (AuNP-LFIAs) possess the advantages of one-step detection and do not require specialized equipment and direct visual readout [17]. Therefore, they have tremendous potential for on-site rapid testing and have been used to detect various small-molecule pesticides, such as quizalofop-p-ethyl [20], quinclorac [15], and deoxynivalenol [21]. However, no AuNP-LFIA-based monoclonal antibody has been reported for CAP.…”
Section: Introductionmentioning
confidence: 99%