2022
DOI: 10.4014/jmb.2109.09022
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Detection of Clostridium tetani by Recombinase Polymerase Amplification Using an Exo Probe

Abstract: Previous research indicates that the structural gene coding for the neurotoxin is on a plasmid [1,2]. The neurotoxin can be endocytosed by both Rab5-and clathrin-dependent mechanisms and then transported to the central nervous system (CNS) by long-distance retrograde axonal transport, where it can inhibit the release of neurotransmitters in the spinal cord, leading to periodic hyper contraction of skeletal muscles (termed spastic paralysis) [3]. The spores of C. tetani are abundantly found in soil and other en… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 41 publications
0
5
0
1
Order By: Relevance
“…Isolated C. tetani from Ind-7 and Ind-44 were deposited in the Collection de Souches de l’Unité des Rickettsies (IHU Méditerranée Infection, Marseille, France) under reference numbers CSUR Q7451 and CSUR Q7452, respectively. Further, toxigenic C. tetani strains were confirmed by aDNA PCR amplification and sequencing of a 240-bp TeNT fragment in Ind-7 and Ind-44 dental pulps (data not shown)(11). C. tetani was not detected by the two different paleoculturomics and paleomicrobiology approaches in the sediments and calculus surrounding the C. tetani -positive teeth.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…Isolated C. tetani from Ind-7 and Ind-44 were deposited in the Collection de Souches de l’Unité des Rickettsies (IHU Méditerranée Infection, Marseille, France) under reference numbers CSUR Q7451 and CSUR Q7452, respectively. Further, toxigenic C. tetani strains were confirmed by aDNA PCR amplification and sequencing of a 240-bp TeNT fragment in Ind-7 and Ind-44 dental pulps (data not shown)(11). C. tetani was not detected by the two different paleoculturomics and paleomicrobiology approaches in the sediments and calculus surrounding the C. tetani -positive teeth.…”
Section: Resultsmentioning
confidence: 96%
“…To confirm the presence of C. tetani in the ancient pulps, a PCR targeting a 240-bp tetanospasmin (tent) gene of C. tetani was performed, using the following primers set by Guo et al , 2012 (11): F1-ATGCGCCATCGTATACTAAC; R1-CCATCTTTCGGATAACCTACA; F2-TATGTATTTGACAAATGCG; R2-CTTTCGGATAACCTACAAT. The thermal profile included an initial five-minute denaturation step at 95 °C followed by 45 cycles consisting of 30 seconds of dissociation at 95 °C, 30 seconds of annealing at 51 °C and 60 seconds elongation at 72 °C.…”
Section: Methodsmentioning
confidence: 99%
“…Recently, the DETECTR method has been established by combining the CRISPR/Cas system with the recombinase polymerase amplification (RPA) system for highly sensitive and specific nucleic acid detection. The RPA system can amplify targeted double-stranded DNA (dsDNA) isothermally at 37–42 °C without a thermocycler, showing great suitability for on-site testing . The RPA assay could improve the sensitivity of the CRISPR/Cas12a assay .…”
Section: Introductionmentioning
confidence: 99%
“…The RPA system can amplify targeted double-stranded DNA (dsDNA) isothermally at 37−42 °C without a thermocycler, showing great suitability for on-site testing. 12 The RPA assay could improve the sensitivity of the CRISPR/Cas12a assay. 13 On the other hand, the CRISPR/Cas12a system could boost the specificity of RPA, and the sequence-specific recognition of the CRISPR system could reduce false-positive results caused by the RPA products.…”
Section: Introductionmentioning
confidence: 99%
“…Although this agarose gel electrophoresis combined with RPA technique has been used in some pathogens detection, it is not optimistic for POCT detection. In addition, more and more literatures have combined RPA with lateral flow test strip (LFS) or fluorescence method to achieve real-time visualization of results ( Ji et al., 2023 ; Guo et al., 2022 ). Although some portable fluorescence reading devices have been widely used, considering the cost of the instrument, this study did not adopt the experimental design combined with fluorescence method at the beginning of design.…”
Section: Introductionmentioning
confidence: 99%