Rapid determination of acetaminophen and p-aminophenol in pharmaceutical formulations using miniaturized capillary electrophoresis with amperometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
55
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 147 publications
(55 citation statements)
references
References 27 publications
0
55
0
Order By: Relevance
“…Acetaminophen (paracetamol, N-acetyl-p-aminophenol, AC) ( Figure 1b) is an extensively used antipyretic analgesic drug and a suitable alternative for patients who are sensitive to aspirin [13]. To date, various methods have been developed for the detection AC such as HPLC [14], spectrophotometry [15], and electrophoresis [16]. Alternatively, electrochemical methods have also received much interest due to their higher selectivity, lower cost, and faster operation than other methods.…”
Section: Introductionmentioning
confidence: 99%
“…Acetaminophen (paracetamol, N-acetyl-p-aminophenol, AC) ( Figure 1b) is an extensively used antipyretic analgesic drug and a suitable alternative for patients who are sensitive to aspirin [13]. To date, various methods have been developed for the detection AC such as HPLC [14], spectrophotometry [15], and electrophoresis [16]. Alternatively, electrochemical methods have also received much interest due to their higher selectivity, lower cost, and faster operation than other methods.…”
Section: Introductionmentioning
confidence: 99%
“…This increases robustness and portability. A miniaturized CE system with AmpD was presented by Chu et al for several applications (e.g., determination of sugars in Coke [98], acetaminophen and p-amino-phenol [99], uric acid in human saliva and urine [100] and bioactive amines [101]). This system was a chipbased design, where an 8.5 cm long capillary was placed on a Plexiglass plate (25 mm x 100 mm x 2 mm).…”
Section: Capillarymentioning
confidence: 99%
“…Miniaturized AmpD has been presented in number of papers [96,[98][99][100][101][107][108][109][110]. The preferred arrangement is based on placing the detection and the separation (capillary) part on the microscope plate, which limits size and increases compactness.…”
Section: Electrochemicalmentioning
confidence: 99%
“…The arrangement of AD was based on the end-column approach and has been described previously [32,33]. The carbon disc electrode was made of polymer leads (diameter 0.3 mm, hardness HB, Sakura, Japan).…”
Section: Instrumentationmentioning
confidence: 99%