2018
DOI: 10.1007/s12161-018-1334-7
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Determination of Capsaicin and Dihydrocapsaicin in Fermented Pepper Paste by Direct Analysis in Real Time Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…Apart from the various applications of DART‐MS for the analysis of oil and honey, it has been demonstrated for the analysis of other viscous food samples. For example, DART‐MS/MS has been used to estimate the concentration of capsaicin and dihydrocapsaicin in fermented pepper paste with LODs at 0.0234 and 0.0510 g/mL, respectively 88 . The results obtained using the DART‐MS/MS method were consistent with those using LC/MS, indicating that DART‐MS could be a suitable high‐throughput tool for the determination of capsaicin and dihydrocapsaicin concentration in food products.…”
Section: Applications Of Dart‐ms In Different Types Of Foodsmentioning
confidence: 60%
“…Apart from the various applications of DART‐MS for the analysis of oil and honey, it has been demonstrated for the analysis of other viscous food samples. For example, DART‐MS/MS has been used to estimate the concentration of capsaicin and dihydrocapsaicin in fermented pepper paste with LODs at 0.0234 and 0.0510 g/mL, respectively 88 . The results obtained using the DART‐MS/MS method were consistent with those using LC/MS, indicating that DART‐MS could be a suitable high‐throughput tool for the determination of capsaicin and dihydrocapsaicin concentration in food products.…”
Section: Applications Of Dart‐ms In Different Types Of Foodsmentioning
confidence: 60%
“…Direct sampling methods like thread spray ionization-MS allowed in situ trace analysis of capsaicinoids without distortion of the samples . Direct analysis in real time (DART) coupled with MS/MS displayed a detection limit of 0.0234 μg mL –1 for capsaicin and 0.0510 μg mL –1 for dihydrocapsaicin, respectively, in fermented chili pepper paste . Subsequently, DART combined with time-of-flight (ToF)-MS could also successfully detect capsaicin levels in pepper fruit and seeds based on the characteristic m / z values as confirmed by HPLC-DAD data .…”
Section: Detection and Separation Methods For Capsicum Secondary Meta...mentioning
confidence: 99%
“…275 Direct analysis in real time (DART) coupled with MS/MS displayed a detection limit of 0.0234 μg mL −1 for capsaicin and 0.0510 μg mL −1 for dihydrocapsaicin, respectively, in fermented chili pepper paste. 276 Subsequently, DART combined with time-of-flight (ToF)-MS could also successfully detect capsaicin levels in pepper fruit and seeds based on the characteristic m/z values as confirmed by HPLC-DAD data. 277 A hand-held near-infrared spectrometer can rapidly detect the capsaicin content and adulteration in pepper powder on site based on selective ensemble preprocessing and machine learning.…”
Section: Detection and Separation Methods Formentioning
confidence: 99%
“…For the determination of total capsaicinoid, molecular weight of 1 was used as more than 60% of total capsaicinoid is shared by 1 and up to 90% is contributed jointly by 1 and its very close analogue dihydrocapsaicin. 32,[50][51][52][53] Sensitivity of the method was expressed through LOD and LOQ values. They were determined by the S/N for the signal at δ H 0.94 ppm in the lower concentration range of 1 (0.05-2.00 mg in 600 μL).…”
Section: H Qnmr Methods Development and Validation For Capsaicin (mentioning
confidence: 99%