2013
DOI: 10.1016/j.microc.2012.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of furosemide by combined spot test/diffuse reflectance spectroscopy to detect doping in sport

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…In the search for alternatives that are environmentally more friendly, the use of diffuse reectance spectroscopy has been described for the analysis of drugs, 21,22 pesticides, 23 and other contaminants. 24 The association of diffuse reectance spectroscopy with the spot test is eco-friendly, because it consists of a simple, fast, inexpensive technique that generates small amounts of waste with low toxicity, minimizing or even eliminating risks to the operator or to the environment.…”
Section: Introductionmentioning
confidence: 99%
“…In the search for alternatives that are environmentally more friendly, the use of diffuse reectance spectroscopy has been described for the analysis of drugs, 21,22 pesticides, 23 and other contaminants. 24 The association of diffuse reectance spectroscopy with the spot test is eco-friendly, because it consists of a simple, fast, inexpensive technique that generates small amounts of waste with low toxicity, minimizing or even eliminating risks to the operator or to the environment.…”
Section: Introductionmentioning
confidence: 99%
“…The limit of detection (LOD) and limit of quantification (LOQ) were determined according to IUPAC recommendations 25 LOD = 3 ×(s/S) and LOQ = 10 ×(s/S), where ''s'' is the standard deviation of measurements of the blank (n = 10) and ''S'' is the slope of the linear dynamic range. 26 The LOD and LOQ were 0.05 and 0.5 mg/L, respectively.…”
Section: Validation Of the Proposed Methodsmentioning
confidence: 94%
“…Possible matrix interferences were studied using standard additions, and the accuracy of the method was tested using the recovery of Al. 26 Recovery tests were performed by water sample and jellyfish sample with known amounts of Al standard, followed by detection using the proposed method. The results obtained for jellyfish and water samples are presented in Table 1.…”
Section: Validation Of the Proposed Methodsmentioning
confidence: 99%
“…Paper provides a good solid platform for diffuse reflectance measurements, due its high contrast and bright white background [22]. Paper platforms can be obtained from renewable sources and require the use of minimal volumes of reagent and sample, generating a negligible waste that is easily incinerated [23]. In order to improve the analytical response and color uniformity, the paper platforms used for spot tests can be impregnated with wax, creating hydrophobic barriers so that the solutions applied are restricted to the delimited area [24].…”
Section: Introductionmentioning
confidence: 99%