Rapid determination of human globin chains using reversed-phase high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…19,20 The ζ globin chain level was determined using a previously described method. 21 The expression of cluster of differentiation (CD)44 in mature erythrocytes was assessed by flow cytometry.…”
Section: Hematological and Biochemical Testsmentioning
confidence: 99%
“…19,20 The ζ globin chain level was determined using a previously described method. 21 The expression of cluster of differentiation (CD)44 in mature erythrocytes was assessed by flow cytometry.…”
Section: Hematological and Biochemical Testsmentioning
confidence: 99%
“…Toward lowered backpressure and greatest peak capacity and thus possibly reduced separation times, an HPLC column with core-shell technology was chosen. 51 The specific column, a Phenomenex Aeris Widepore XP-C18, was selected as a replacement of a previous fully porous C18 column, 38 , 39 and has certified stability at pH 1.5–9.0, at backpressures up to 600 bar (60 MPa) and at temperatures up to 90°C. To minimize background noise in the analysis of rare samples at far-UV absorbance measurements, the study additionally drew on acetonitrile supplemented with 0.1% TFA without inclusion of other organic solvents as the organic mobile phase.…”
Section: Resultsmentioning
confidence: 99%
“…In line with routine procedures for RP-HPLC analysis of thalassemic samples, 38 , 39 , 50 blood samples were lysed in HPLC-quality distilled water (H 2 O; 4 μL of PB in 996 μL of H 2 O), vortexing and incubating at room temperature for 10 min. For cell culture samples, the sample material was centrifuged at 2,000 RCF for 10 min, re-suspended in 15 μL of H 2 O/300,000 cells, and twice frozen at −80°C and thawed.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, although it is widely used for the detection, quantification and purification of many proteins from biological materials, its clinical application for hemoglobins is still limited due to the long analytical time, complex sample preparation and resolution problems. 40,41 Recently, studies have had success in optimizing the method, 40,41 but in many laboratories the technique is still employed exclusively for research.…”
Section: Introductionmentioning
confidence: 99%