2004
DOI: 10.1016/j.aca.2004.04.050
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of trace levels of tetracyclines in surface water using a continuous flow manifold coupled to a capillary electrophoresis system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
42
0
2

Year Published

2006
2006
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 76 publications
(44 citation statements)
references
References 18 publications
0
42
0
2
Order By: Relevance
“…Figure 7 shows the electropherogram corresponding to a water sample spiked with a 5 ng/mL concentration of each tetracycline derivative. This CE method enabled the detection up to 2 ng/mL of tetracyclines in water samples [21]. …”
Section: Antibiotics In Environmental Samples: Their Role As Emergingmentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 7 shows the electropherogram corresponding to a water sample spiked with a 5 ng/mL concentration of each tetracycline derivative. This CE method enabled the detection up to 2 ng/mL of tetracyclines in water samples [21]. …”
Section: Antibiotics In Environmental Samples: Their Role As Emergingmentioning
confidence: 99%
“…In this sense, offline sample treatment by SPE, LLE, and SLE has been performed. However, the online coupling of sample treatment systems to CE seems to be very promising because it enables the automatization of the analytical process, one interesting example being included in this review [21]. In addition, these sample treatment procedures can concentrate antibiotic samples prior to the injection in the CE system.…”
Section: Conclusion and Future Prospectsmentioning
confidence: 99%
See 1 more Smart Citation
“…Different analytical techniques have been developed for determination of terbutaline sulfate and tetracycline. HPLC, 8,9 LC-MS, 10 CE, 11 CE-MS, 12 voltammetry, 13 electrochemical method, 14,15 liquid chromatography, 16,17 capillary electrophoresis 18 and chemiluminescence 19,20 have been reported for determination of tetracycline. These methods are often time-consuming, expensive, and cumbersome.…”
Section: Introductionmentioning
confidence: 99%
“…There are several analytical methods used to detect tetracyclines with different matrices, for example liquid-chromatography (LC) and fluorescence detection (13,24), as well as capillary electrophoresis (CE) using laser-induced fluorescence detection (21). LC with UV detection (5,7,9,16,19) has been also employed.…”
Section: Introductionmentioning
confidence: 99%