2021
DOI: 10.3389/fenvs.2021.746195
|View full text |Cite
|
Sign up to set email alerts
|

Rapid In-Field Approaches for Delineating VOC in Both Soil Vapour and Groundwater for Vapour Intrusion Assessment

Abstract: Traditional contaminated site characterisation approaches are time-consuming, labour-intensive, and demand a high level of expertise. This case study provides a rapid field-based solution to investigating a VOC contaminated site and its vapour incursion by combining soil vapour and groundwater survey. To fully assess the volatile organic compound (VOC) distribution in a contaminated site, a number of self-developed soil vapour sampling probes (SVSPs) were placed vertically at different locations in a grid with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…A field-portable Torion-T9 GC-MS, which provides analytical information that is definitive for many types of samples containing the organic analyte(s) using solidphase microextraction (SPME) and Needle Trap as the default sampling method. As demonstrated in our previous study (Wang et al, 2021a;Wang et al, 2021b), Torion-T9 portable GC-MS can provide results within minutes and is suitable for on-site analysis.…”
Section: In Situ Measurementmentioning
confidence: 72%
“…A field-portable Torion-T9 GC-MS, which provides analytical information that is definitive for many types of samples containing the organic analyte(s) using solidphase microextraction (SPME) and Needle Trap as the default sampling method. As demonstrated in our previous study (Wang et al, 2021a;Wang et al, 2021b), Torion-T9 portable GC-MS can provide results within minutes and is suitable for on-site analysis.…”
Section: In Situ Measurementmentioning
confidence: 72%
“…For subppb or ppt level detection, preconcentration technology, such as solid-state microextraction fiber, can be applied for sampling and preconcentration. The preconcentration technologies have been widely applied to μGC-MS. , …”
Section: Perspective and Discussionmentioning
confidence: 99%
“…For subppb or ppt level detection, preconcentration technology, such as solid-state microextraction fiber, can be applied for sampling and preconcentration. The preconcentration technologies have been widely applied to μGC-MS. 6,7 Advanced MOS and eNose. According to the literature, 62,65 MO sensor arrays and data analysis algorithms, such as eNose, can aid in detecting multiple gases simultaneously.…”
Section: ■ Perspective and Discussionmentioning
confidence: 99%
See 2 more Smart Citations