2009
DOI: 10.1002/jcla.20345
|View full text |Cite
|
Sign up to set email alerts
|

Rapid liquid chromatography/tandem mass spectrometer (LCMS) method for clozapine and its metabolite N‐desmethyl Clozapine (Norclozapine) in human serum

Abstract: Clozapine is indicated for the treatment of schizophrenia and related psychotic disorders. Several methods have been developed for monitoring Clozapine levels; however, they possess limited specificity and are often laborious. This study describes a simple liquid chromatography/tandem mass spectrometer (LCMS) method in human serum. The ion transitions monitored were m/z 327, 270, 296 for Clozapine, m/z 313, 192, 227 for Norclozapine and m/z 328, 271 for Loxapine. The assay is linear (25-1000 ng/ml) and showed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…Because, leucocytes are activated in EAE, it is possible that immune cells are responsible for an increase in α-1-acid glycoprotein, which binds and retains clozapine in the blood. Peak serum levels of clozapine are reached 1-6 h after oral dosing and the half-life is about 4 to 16 h in healthy adults 42 , and our findings suggest this half-life may be extended during a neuroinflammatory response. MALDI IMS was used for the first time to analyse the distribution of unlabelled clozapine within the brain tissue from healthy and EAE mice.…”
Section: Discussionmentioning
confidence: 49%
“…Because, leucocytes are activated in EAE, it is possible that immune cells are responsible for an increase in α-1-acid glycoprotein, which binds and retains clozapine in the blood. Peak serum levels of clozapine are reached 1-6 h after oral dosing and the half-life is about 4 to 16 h in healthy adults 42 , and our findings suggest this half-life may be extended during a neuroinflammatory response. MALDI IMS was used for the first time to analyse the distribution of unlabelled clozapine within the brain tissue from healthy and EAE mice.…”
Section: Discussionmentioning
confidence: 49%
“…Rapid detection of clozapine and norclozapine by liquid chromatography/tandem mass spectrometry (LCMS) technology has been previously described. 18 Full details are available in the Supplementary methods.…”
Section: Methodsmentioning
confidence: 99%
“…The NQAD is claimed to have superior linearity compared with other aerosol-based detectors, covering several orders of magnitude for most analytes (http://www.quant-nqad.com). Quantification by HPLC/ MSD is also normally known to deliver a good linear detector response [25,26]. With regard to NMR spectroscopy, linearity is given over a rather broad range since the intensity of a signal is directly proportional to the number of nuclei being observed [17,27] under well-defined experimental conditions (e.g.…”
Section: Linearity Of Rangementioning
confidence: 99%