2016
DOI: 10.1007/s10967-016-4783-8
|View full text |Cite
|
Sign up to set email alerts
|

Rapid method to determine actinides and 89/90Sr in limestone and marble samples

Abstract: A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89/90 Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. This approach has a sample preparation time for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…Therefore, the removal of impurities and salts in the fused samples should be carried out before the stage of chemical separations. Coprecipitation is well known method to remove impurities and salts in the fused samples [38,39].…”
Section: Dissolution and Preconcentration Of Samplesmentioning
confidence: 99%
“…Therefore, the removal of impurities and salts in the fused samples should be carried out before the stage of chemical separations. Coprecipitation is well known method to remove impurities and salts in the fused samples [38,39].…”
Section: Dissolution and Preconcentration Of Samplesmentioning
confidence: 99%
“…Since the fluoride ion will attack Zr metal, only HCl and HNO 3 were used in the initial steel dissolution. Once the digestate was evaporated to dryness, sodium hydroxide pellets were added, and the sample was fused and processed as described previously [5], except that no additional Fe was added. In this fusion option, an initial precipitation is performed using iron hydroxide enhanced with calcium phosphate to remove the high levels of hydroxide.…”
Section: Measurement Of Column Capacity Factors (K')mentioning
confidence: 99%
“…Sr is separated using Sr Resin (3 mL Sr Resin, using stacked 2 mL+1 mL resin cartridges) using a method similar to that previously published for the determination of 89 Sr and 90 Sr in limestone and marble samples. [5] The sample load solutions were added to the Sr Resin at approximately 1 drop per second. After the sample was loaded, the sample tube was rinsed with 5 mL 8M HNO 3 , which was transferred to the Sr Resin column and allowed to pass through the resin at ~1-2 drops per second.…”
Section: Measurement Of Column Capacity Factors (K')mentioning
confidence: 99%
See 1 more Smart Citation
“…This includes recently published methods for soil, concrete, limestone and marble. [5,6] These radiochemical methods are both rapid and reliable, offering highly defensible quality.…”
Section: Introductionmentioning
confidence: 99%