2002
DOI: 10.1006/fstl.2001.0804
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Preconcentration and Enrichment Techniques for the Analysis of Food Volatile. A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
58
0

Year Published

2006
2006
2012
2012

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 120 publications
(58 citation statements)
references
References 109 publications
0
58
0
Order By: Relevance
“…In this method, the sample is introduced into a dynamic headspace vial which is thermostated for a time to increase the fugacity of volatile compounds, and subsequently, for a few M. NARváEz-RIvAS, E. GAllARDo AND M. lEóN-CAMACHo minutes the volatile substances are purged with purified helium and adsorbed into a capillary Tenax trap held at a low temperature with liquid nitrogen. After adsorption onto a sorbent, the trapped compounds are desorbed by heating and then cryofocused at the head of the gas chromatograph-column (Pillonel et al, 2002). The analytes can also be eluted with a solvent (Burger and Munro, 1987;olafsdottir et al, 1985) but recovery is not always satisfactory (Boren et al, 1985) and is difficult to automate.…”
Section: Dynamic Headspace (Purge and Trap)mentioning
confidence: 99%
See 1 more Smart Citation
“…In this method, the sample is introduced into a dynamic headspace vial which is thermostated for a time to increase the fugacity of volatile compounds, and subsequently, for a few M. NARváEz-RIvAS, E. GAllARDo AND M. lEóN-CAMACHo minutes the volatile substances are purged with purified helium and adsorbed into a capillary Tenax trap held at a low temperature with liquid nitrogen. After adsorption onto a sorbent, the trapped compounds are desorbed by heating and then cryofocused at the head of the gas chromatograph-column (Pillonel et al, 2002). The analytes can also be eluted with a solvent (Burger and Munro, 1987;olafsdottir et al, 1985) but recovery is not always satisfactory (Boren et al, 1985) and is difficult to automate.…”
Section: Dynamic Headspace (Purge and Trap)mentioning
confidence: 99%
“…The analytes can also be eluted with a solvent (Burger and Munro, 1987;olafsdottir et al, 1985) but recovery is not always satisfactory (Boren et al, 1985) and is difficult to automate. However, thermal desorption shows the following advantages: analysis of 100% of the trap content, no solvent peak, no waste and no contamination from the solvent (Pillonel et al, 2002).…”
Section: Dynamic Headspace (Purge and Trap)mentioning
confidence: 99%
“…The DVB/CAR/PDMS fiber is made of a layer of PDMS-CAR, where small molecules with high diffusion coefficients are adsorbed onto the Carboxen, and is also covered by a second layer of PDMS-DVB, where the heavier molecules are retained in the outer of the DVB layer. 19 This fiber has previously shown more affinity to aldehyde compounds than CAR/PDMS fiber which was better to evaluate ester compounds. 2 DVB/CAR/ PDMS fiber was also used for hexanal determination in frankfurters 8 and pressurized chicken; 12 while CAR/PDMS fiber was used for hexanal determination in pressurized chicken, 7 PDMS/DVB fiber was used for hexanal and pentanal determination in cooked turkey, 9 and PDMS fiber was used for hexanal determination in freeze dried chicken myofibrils 10 and minced pork.…”
Section: Optimization Of Spme Conditionsmentioning
confidence: 99%
“…For this purpose, liquid-liquid extraction (LLE) followed by gas chromatography coupled to mass spectrometry using the common quadrupole analyser (GC-MS) has been the analytical method of choice. Nevertheless, LLE is a time consuming and labour intensive technique, involving multi-step procedures and use of toxic solvents [2]. Nowadays, the solventless approaches such as solid phase microextraction (SPME) and, more recently, stir bar sorptive extraction (SBSE), showed to be environmental friendly alternatives due to its easy of use, high selectivity, high sensitivity and reproducibility, and less time consuming than the conventional techniques for which the most important theoretical considerations have been already described [3,4].…”
Section: Introductionmentioning
confidence: 99%