Rapid Screening of Environmental Chemicals for Estrogen Receptor Binding Capacity

Abstract: Over the last few years, an increased awarenes of endocrine disrupting chemicals (EDCs)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

12
113
2

Year Published

2001
2001
2013
2013

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(127 citation statements)
references
References 37 publications
(53 reference statements)
12
113
2
Order By: Relevance
“…E2 and OHT were tested as positive controls to validate the SPR method. The K D value of E2 (0.31 nM) obtained in our assay is in good agreement with the results of fluorescence polarization (0.6 nM), 33 radio-labeled competitive assay (0.26 nM, 0.13 nM) 34,35 and SPR based assay (0.9 nM). 30 The K D value of OHT (5.7 nM) is also within the range of 0.2−18 nM obtained by other reported methods.…”
Section: ■ Results and Discussionsupporting
confidence: 89%
“…E2 and OHT were tested as positive controls to validate the SPR method. The K D value of E2 (0.31 nM) obtained in our assay is in good agreement with the results of fluorescence polarization (0.6 nM), 33 radio-labeled competitive assay (0.26 nM, 0.13 nM) 34,35 and SPR based assay (0.9 nM). 30 The K D value of OHT (5.7 nM) is also within the range of 0.2−18 nM obtained by other reported methods.…”
Section: ■ Results and Discussionsupporting
confidence: 89%
“…Both the EC 50 values in the receptor binding assay of bisphenol A and 4,4-OHBP (Bolger et al 1998;Kuiper et al 1998) and the growth stimulation of 4-OHBP, 4,4-OHBP and bisphenol A were in the same range as reported by others (Soto et al 1995). In accordance with the relatively low binding affinity to the oestrogen receptors, all the chemicals tested expressed a much lower proliferative potential than 17b-oestradiol (table 1).…”
Section: Discussionsupporting
confidence: 75%
“…The introduction of fluorescent probes, has made possible the measurement of relative binding affinities using fluorescence polarization by the utilization of fluorescein-labeled E2 (Bolger et al, 1998). The radio-labeled version of the ligand-ER binding assay has the advantage to allow the measurements of the binding activity of purified compounds on both crude protein extracts and intact living cells expressing ERs.…”
Section: ( ( ( ( (A) Ligand-er Binding Assays A) Ligand-er Binding Asmentioning
confidence: 99%