Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
43
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 59 publications
(46 citation statements)
references
References 31 publications
2
43
0
1
Order By: Relevance
“…However, by using 17OHP cutoff values adjusted by birthweight and/or gestational age, it was possible to reduce the recall rate from 1.12% to 0.5% in Germany [28]. Other newborn CAH screening protocols with second tier steps such as re-measuring first-tier elevated 17-OHP levels by liquid chromatography-tandem mass spectrometry [38], by steroid profiling of steroids such as 17-OHP, androstenedione, and cortisol [39][40][41][42] and/or by molecular-genetic analyses [43] improve screening effectiveness. According to the results of Kosel et al, further reduction of the recall rates of around 90% without loss of sensitivity was possible by analyzing the CYP21A2-gene as second-tier [44].…”
Section: Problems With False-positive and False Negative-resultsmentioning
confidence: 99%
“…However, by using 17OHP cutoff values adjusted by birthweight and/or gestational age, it was possible to reduce the recall rate from 1.12% to 0.5% in Germany [28]. Other newborn CAH screening protocols with second tier steps such as re-measuring first-tier elevated 17-OHP levels by liquid chromatography-tandem mass spectrometry [38], by steroid profiling of steroids such as 17-OHP, androstenedione, and cortisol [39][40][41][42] and/or by molecular-genetic analyses [43] improve screening effectiveness. According to the results of Kosel et al, further reduction of the recall rates of around 90% without loss of sensitivity was possible by analyzing the CYP21A2-gene as second-tier [44].…”
Section: Problems With False-positive and False Negative-resultsmentioning
confidence: 99%
“…1), in contrast with the only two assays previously reported to use DBSs for the determination of these analytes [16,17]. Our assay was successfully applied in the cross-border cooperation for newborn screening of CAH.…”
Section: Discussionmentioning
confidence: 95%
“…This requires separation of the isobaric analytes 21-deoxycortisol (21-Deox) and 11-deoxycortisol (11-Deox), specific to these two forms of CAH [1,2,3]. Most previous assays for 21-Deox and 11-Deox did not allow an analysis of DBSs [9,10,11,12,13,14,15], and those which did achieved acceptable but not baseline resolution of these isobaric compounds [16,17]. …”
Section: Introductionmentioning
confidence: 99%
“…104 Mass spectrometric methods have been introduced as second tier tests. [105][106][107][108] Transient high 17-OHP has been seen in premature infants. 109 Since the clinical condition will require life-long treatment, a sound confirmation of the defect is required.…”
Section: Clinical Uses and Limitations Of 17-ohp Measurements Classicmentioning
confidence: 99%