Rapidly, sensitive quantitative assessment of thiopental via forced stability indicating validated RP-HPLC method and its in-use stability activities

Abstract: Thiopental sodium (Tho) is an intravenous anesthetic. The current study aimed to find a rapid RP-HPLC method of Tho analysis with high linearity, repeatability, sensitivity, selectivity, and inexpensive. In our developed method, there is no need to use special chemical reagents, a high percentage of organic solvent, a high flow rate, or a further guard column. The chromatographic system consists of an ODS column (150 mm × 4.6 mm × 5 μm). The mobile phase was prepared by mixing KH2PO4 solution: methanol (40:60)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 52 publications
0
9
0
Order By: Relevance
“…Under the optimized parameters of the analytical method, these ranged from 2.1 to 2.4 and 3.4 to 3.9 minutes for Cpx and Cpx-Drv peaks, respectively, over all the parameter changes. Tables 2 and 3 Table 2; Table 3 show the high performance of the intended analysis method where the peak area RSD % ≤ 2.0%, USP tailing ≤ 2.0, theoretical plates ≥ 2000, and resolution ≥ 1.5 [23][24][25]. Hence, based on the obtained system suitability testing data, the method showed excellent validity through a wide range of retention times.…”
Section: Hplc Quantitative Qualitative Analysis and Methods Validatio...mentioning
confidence: 91%
See 1 more Smart Citation
“…Under the optimized parameters of the analytical method, these ranged from 2.1 to 2.4 and 3.4 to 3.9 minutes for Cpx and Cpx-Drv peaks, respectively, over all the parameter changes. Tables 2 and 3 Table 2; Table 3 show the high performance of the intended analysis method where the peak area RSD % ≤ 2.0%, USP tailing ≤ 2.0, theoretical plates ≥ 2000, and resolution ≥ 1.5 [23][24][25]. Hence, based on the obtained system suitability testing data, the method showed excellent validity through a wide range of retention times.…”
Section: Hplc Quantitative Qualitative Analysis and Methods Validatio...mentioning
confidence: 91%
“…Both are two sides of the same coin and are used interchangeably. Accuracy describes the degree of closeness of the measured concentration value to the claimed theoretical concentration [23,24]. Accuracy was determined by weighing three different weights for each of Cpx and Cpx-Drv to produce theoretical concentrations at 35 µg/mL, 50 µg/mL, and 60 µg/mL.…”
Section: Accuracy and Recoverymentioning
confidence: 99%
“…The free AZM concentration was measured according to the previously reported work ( Al-Hakkani, 2019c ; Al-Hakkani et al, 2022b ). All experiments were repeated three times, and the average values were determined following validation protocols to ensure high accuracy and precision ( Al-Hakkani, 2019a , Al-Hakkani, 2019b , Al-Hakkani, 2019c ; Al-Hakkani, 2023 ; Al-Hakkani et al, 2023a ; Al-Hakkani et al, 2023b ; Al-Hakkani et al, 2021b ; Al-Hakkani et al, 2022c ).…”
Section: Methodsmentioning
confidence: 99%
“…Ruggedness was submitted using designed and major observable changes including analyst-analyst, column-column, and day-day with maintaining all the analysis method parameters and conditions as it is without changes [ 37 ].…”
Section: Methodsmentioning
confidence: 99%