2016
DOI: 10.1177/0144598715623673
|View full text |Cite
|
Sign up to set email alerts
|

Rare gases geochemical characteristics and gas source correlation for Dabei gas field in Kuche depression, Tarim Basin

Abstract: The total components and isotopes of rare gases as well as hydrocarbon gases for Dabei gas field are analyzed firstly, then their geochemical characteristics and genesis are discussed respectively, finally gas source correlation and their contributions are evaluated. The research results show that: (1) In Dabei gas field, methane is the main component, accompanying with a few N 2 and CO 2 , as well as extremely low rare gases. In total component contents of rare gases, the He content is from 56.0 to 60.4 ppm w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 29 publications
0
13
0
Order By: Relevance
“…(6) Finally, the separated rare gases were sent into rare gas isotope mass spectrometer to determine their isotopic compositions by method of peak height ratio on ion current signal intensity. The accuracies of molecular composition abundances of rare gases helium, neon, argon, krypton, and xenon were estimated to be ±3.36%, ±3.66%, ±1.32%, ±2.99%, and ±6.96% [23], and the accuracies of isotopic compositions of rare gases 3 He/ 4 He, 20 Ne/ 22 Ne, 40 Ar/ 36 Ar, 38 Ar/ 36 Ar, 129 Xe/ 130 Xe, and 132 Xe/ 130 Xe were estimated to be ±4.50%, ±1.32%, ±1.27%, ±1.39%, ±1.63%, ±1.84%, and ±2.13%, respectively.…”
Section: Methodsmentioning
confidence: 98%
See 4 more Smart Citations
“…(6) Finally, the separated rare gases were sent into rare gas isotope mass spectrometer to determine their isotopic compositions by method of peak height ratio on ion current signal intensity. The accuracies of molecular composition abundances of rare gases helium, neon, argon, krypton, and xenon were estimated to be ±3.36%, ±3.66%, ±1.32%, ±2.99%, and ±6.96% [23], and the accuracies of isotopic compositions of rare gases 3 He/ 4 He, 20 Ne/ 22 Ne, 40 Ar/ 36 Ar, 38 Ar/ 36 Ar, 129 Xe/ 130 Xe, and 132 Xe/ 130 Xe were estimated to be ±4.50%, ±1.32%, ±1.27%, ±1.39%, ±1.63%, ±1.84%, and ±2.13%, respectively.…”
Section: Methodsmentioning
confidence: 98%
“…Molecular composition abundances and isotopic compositions of rare gases were measured in the Key Laboratory of Gas Reservoir Formation and Development of CNPC. In order to reduce impacts of rare gases in the air on sampling and experimentation and obtain correct rare gas analyzed results, some special gas sample collecting methods were adopted [23]. The detailed analytic processes were listed as follows [15,23].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations