1985
DOI: 10.1136/adc.60.1.66
|View full text |Cite
|
Sign up to set email alerts
|

Re-evaluation of saliva for monitoring theophylline concentrations.

Abstract: 6 Manciaux M. 'Some monographs' in children and accidents. Children in the tropics 1980;123:6-10. 7 Mero Asagba GEE. Three villages' memory of accidents involving children in thrcc gencrations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

1986
1986
1996
1996

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Monitoring of serum theophylline levels is well established because of the narrow range of optimal serum concentration and the great interindividual differences in pharmacokinetics especially in ~h i l d r e n .~.~ Knowledge of theophylline levels is also useful in assessing and improving patient ~o m p l i a n c e .~ In order to make theophylline drug monitoring more convenient for the patient, numerous investigators have studied the accuracy of salivary theophylline levels in predicting serum levels and have obtained conflicting results . [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19] In this study we have investigated the accuracy and predictive value of saliva theophylline measurements using fluorescence polarization immunoassay (FPIA), which has been proven to be a reliable The Seralyzer (reagent strip reflectance photometer method), which can be used for rapid theophylline determination in an ambulatory setting,21,22 was simultaneously tested. We tried to make sampling of saliva easier by using a special device.…”
Section: Introductionmentioning
confidence: 99%
“…Monitoring of serum theophylline levels is well established because of the narrow range of optimal serum concentration and the great interindividual differences in pharmacokinetics especially in ~h i l d r e n .~.~ Knowledge of theophylline levels is also useful in assessing and improving patient ~o m p l i a n c e .~ In order to make theophylline drug monitoring more convenient for the patient, numerous investigators have studied the accuracy of salivary theophylline levels in predicting serum levels and have obtained conflicting results . [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19] In this study we have investigated the accuracy and predictive value of saliva theophylline measurements using fluorescence polarization immunoassay (FPIA), which has been proven to be a reliable The Seralyzer (reagent strip reflectance photometer method), which can be used for rapid theophylline determination in an ambulatory setting,21,22 was simultaneously tested. We tried to make sampling of saliva easier by using a special device.…”
Section: Introductionmentioning
confidence: 99%
“…2 Theophylline concentrations measured in saliva have been shown to be unreliable. 3 Various techniques are used to measure theophylline concentrations in serum. The purpose of this study was to compare results obtained by high performance liquid chromatography (HPLC) with those of a simple stick assay carried out at the bedside.…”
mentioning
confidence: 99%