2006
DOI: 10.1590/s0100-72032006001200007
|View full text |Cite
|
Sign up to set email alerts
|

Reação anafilática ao corante azul patente durante a biópsia do linfonodo sentinela em câncer de mama inicial: relato de caso

Abstract: A biópsia do linfonodo sentinela no tratamento do câncer de mama vem substituindo a linfadenectomia em casos iniciais. Este tratamento pode ser realizado com o corante azul vital e/ou radiofármaco. Há relatos de reações alérgicas ao corante com diferentes graus de severidade. Relata-se um caso de reação anafi lática severa após injeção intradérmica do corante azul patente, em paciente com diagnóstico de carcinoma ductal in situ. O corante azul patente, apesar de facilitar a detecção do linfonodo, apresenta ris… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0
11

Year Published

2014
2014
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(23 citation statements)
references
References 16 publications
0
12
0
11
Order By: Relevance
“…None of the animals used in this study exhibited immediate or late hypersensitivity reactions such as those described in the literature in humans (Del massa et al 2005, Shinzato et al 2006, Jeudy et al 2008, Bricou et al 2009, Hunting et al 2010, Lucas et al 2010, Rodrigues et al 2010, Hou-Chuan Lai et al 2011. According to the patient information leaflet, whatever is the route of administration, the Patent Bleu V ® solution (2.5%) is excreted within 24 to 48 hours in the bile and urine, the latter being more strongly colored.…”
Section: Discussionmentioning
confidence: 80%
“…None of the animals used in this study exhibited immediate or late hypersensitivity reactions such as those described in the literature in humans (Del massa et al 2005, Shinzato et al 2006, Jeudy et al 2008, Bricou et al 2009, Hunting et al 2010, Lucas et al 2010, Rodrigues et al 2010, Hou-Chuan Lai et al 2011. According to the patient information leaflet, whatever is the route of administration, the Patent Bleu V ® solution (2.5%) is excreted within 24 to 48 hours in the bile and urine, the latter being more strongly colored.…”
Section: Discussionmentioning
confidence: 80%
“…Many authors have described systemic cardiovascular signals associated with hypersensitivity in humans, and hypotension was the most cited (Shinzato et al 2006, Bricou et al 2009, Hunting et al 2010, Lucas et al 2010. Hypotension caused by an anaphylactic reaction to dyes can be confused with the hypotension commonly observed during anesthesia and is usually reversed by the pain stimuli from the surgical procedure, superficialization of anesthetic level, and an increase in intravenous fluids (Hunting et al 2010).…”
Section: Discussionmentioning
confidence: 99%
“…The use of blue dyes associated, or not, with local anesthetics can cause allergic reactions, suggesting that blue dye itself is a potential allergen (Hirsch et al 1982). There are no reports of adverse reactions in dogs using patent blue dye, but several reports of anaphylactic reactions are described in humans, with symptoms such as erythema, hypotension, tachycardia, and decreased oxygen saturation (Hirsch et al 1982, Del Massa et al 2005, Shinzato et al 2006, Jeudy et al 2008, Bricou et al 2009, Hunting et al 2010, Lucas et al 2010, Rodrigues et al 2010, Hou-Chuan Lai et al 2011.…”
Section: Introductionmentioning
confidence: 99%
“…1,2 Para identificação do linfonodo pode ser usado o corante azul patente ou o radiofármaco tecnésio, ambos de forma isolada ou em associação. 1 No entanto têm sido relatadas reações de hipersensibilidade, mediada por IgE, ao corante azul patente, em uma incidência média de 1,8% (0,1% a 2,8%), reações essas em alguns casos severas, com repercussões hemodinâmicas graves, que necessitam de drogas vasoativas. [1][2][3][4] Essa frequência é superior à das reações de hipersensibilidade observadas durante a anestesia, que é em torno de 0,01% a 0,02%.…”
Section: Introductionunclassified
“…1 No entanto têm sido relatadas reações de hipersensibilidade, mediada por IgE, ao corante azul patente, em uma incidência média de 1,8% (0,1% a 2,8%), reações essas em alguns casos severas, com repercussões hemodinâmicas graves, que necessitam de drogas vasoativas. [1][2][3][4] Essa frequência é superior à das reações de hipersensibilidade observadas durante a anestesia, que é em torno de 0,01% a 0,02%. 5 Outro efeito observado com o uso do azul patente são as alterações da oximetria de pulso, em função da interferência na leitura do comprimento de onda, usado para medir a oxi-hemoglobina.…”
Section: Introductionunclassified