Reaction Forces and Flexion–Extension Moments Imposed on Functional Spinal Units With Constrained and Unconstrained In Vitro Testing Systems

Abstract: A mechanical goal of in vitro testing systems is to minimize differences between applied and actual forces and moments experienced by spinal units. This study quantified the joint reaction forces and reaction flexion-extension moments during dynamic compression loading imposed throughout the physiological flexion-extension range-of-motion. Constrained (fixed base) and unconstrained (floating base) testing systems were compared. Sixteen porcine spinal units were assigned to both testing groups. Following condit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 44 publications
0
2
0
Order By: Relevance
“…The superior aluminum cup was bolted to the flexion-extension rotation carriage that was actuated by a torque motor (T120-106-1K; Sensor Data Technologies, Sterling Heights, MI) and positioned in series to the compression actuator of a material testing system (Model 8872, Instron, Toronto, ON, Canada). The inferior aluminum cup was secured to an aluminum base that overlaid an oiled bearing covered surface 24. To prevent dehydration, specimens were wrapped with saline-soaked plastic-backed gauze and received additional superficial moistening every 20 minutes.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The superior aluminum cup was bolted to the flexion-extension rotation carriage that was actuated by a torque motor (T120-106-1K; Sensor Data Technologies, Sterling Heights, MI) and positioned in series to the compression actuator of a material testing system (Model 8872, Instron, Toronto, ON, Canada). The inferior aluminum cup was secured to an aluminum base that overlaid an oiled bearing covered surface 24. To prevent dehydration, specimens were wrapped with saline-soaked plastic-backed gauze and received additional superficial moistening every 20 minutes.…”
Section: Methodsmentioning
confidence: 99%
“…The inferior aluminum cup was secured to an aluminum base that overlaid an oiled bearing covered surface. 24 To prevent dehydration, specimens were wrapped with saline-soaked plastic-backed gauze and received additional superficial moistening every 20 minutes.…”
Section: Specimen Preparationmentioning
confidence: 99%