2012
DOI: 10.1016/j.egypro.2012.03.012
|View full text |Cite
|
Sign up to set email alerts
|

Reactive Power Dynamic Assessment of a PV System in a Distribution Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
3
2

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 7 publications
0
17
0
Order By: Relevance
“…cos φ pv,eq = m pv,eq P pv,eq − P th,eq + 1 (16) Q pv,eq = −P pv,eq 1 cos φ pv,eq 2 − 1 (17) where P pv,eq and Q pv,eq are active and reactive power of the equivalent PV model. In power flow simulations of this paper, the individual PV systems and the corresponding equivalent PV are considered as generation units with a power flow direction outward the units as shown in Fig.…”
Section: Model I: Zip/pv Equivalentmentioning
confidence: 99%
“…cos φ pv,eq = m pv,eq P pv,eq − P th,eq + 1 (16) Q pv,eq = −P pv,eq 1 cos φ pv,eq 2 − 1 (17) where P pv,eq and Q pv,eq are active and reactive power of the equivalent PV model. In power flow simulations of this paper, the individual PV systems and the corresponding equivalent PV are considered as generation units with a power flow direction outward the units as shown in Fig.…”
Section: Model I: Zip/pv Equivalentmentioning
confidence: 99%
“…In reference [12], it was demonstrated that a PV-STATCOM can increase the power transfer limits of a transmission system. Reactive power support by one-phase and three-phase single-stage PV systems was also discussed by [13,14,15] focusing on control strategies to keep the converter within its operating limits. However, none of those works discussed the technical cost of operating a PV farm as a STATCOM.…”
Section: Motivationmentioning
confidence: 99%
“…On the other hand, depending on time and weather variability, the simultaneous occurrence of excess intermittent renewable generation (i.e., wind and solar PV) and low demand would lead to loss of voltage regulation along with unexpected voltage-rise on the feeders due to reverse power flows [102]. As a fast response device, the inverter-based PV unit is allowed to inject or absorb reactive power to stabilize load voltages as per the new German grid code [103] while supplying energy as a primary task [101,104]. Other technologies such as synchronous machines used in biomass power plants, and Doubly-Fed Induction Generators (DFIGs) or full converter synchronous machines employed in wind farms are also capable of controlling reactive power while supplying active power [105].…”
Section: Grid Codes For Dg Integrationmentioning
confidence: 99%
“…This study assumes that inverter-based PV units are allowed to inject or absorb reactive power in compliance with the new German grid code [103]. Biomass gas turbines are modelled as synchronous machines.…”
Section: Generation Criteriamentioning
confidence: 99%
See 1 more Smart Citation