2019
DOI: 10.1161/circresaha.119.314862
|View full text |Cite
|
Sign up to set email alerts
|

Reactive Vasodilation Predicts Mortality in Primary Systemic Light-Chain Amyloidosis

Abstract: Supplemental Digital Content is available in the text.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 59 publications
2
20
0
Order By: Relevance
“…To further investigate the endothelial homeostasis as well as the redox status of the carfilzomib- and metformin-treated mice, the total circulating nitrates/nitrites (NO x ) content in the sera as a biomarker of NO release, 3-nitrotyrosine (3-NT), nicotinamide adenine dinucleotide phosphate (NADPH) oxidase 2 ( nox2 ) and NADPH oxidase 4 ( nox4 ) redox-related genes in the aortic tissues as markers of nitro-oxidative stress were assessed [ 12 ]. Neither carfilzomib nor metformin or the drugs coadministration led to any significant changes in NO x and 3-NT content ( Figure 4 A,B), whereas nox2 and nox4 levels did not differ among groups ( Figure 4 C).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…To further investigate the endothelial homeostasis as well as the redox status of the carfilzomib- and metformin-treated mice, the total circulating nitrates/nitrites (NO x ) content in the sera as a biomarker of NO release, 3-nitrotyrosine (3-NT), nicotinamide adenine dinucleotide phosphate (NADPH) oxidase 2 ( nox2 ) and NADPH oxidase 4 ( nox4 ) redox-related genes in the aortic tissues as markers of nitro-oxidative stress were assessed [ 12 ]. Neither carfilzomib nor metformin or the drugs coadministration led to any significant changes in NO x and 3-NT content ( Figure 4 A,B), whereas nox2 and nox4 levels did not differ among groups ( Figure 4 C).…”
Section: Resultsmentioning
confidence: 99%
“…For serum nitrates-nitrites (NO x ) measurements, sera were concentrated using 10 kDa cut-off filters and flow-through sample was further analyzed accordingly to the manufacturer’s instructions using a commercially available kit (No. 780001, Cayman Chemicals) [ 12 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Flow-mediated dilation was assessed using a 7.0 to 14.0 Hz multifrequency linear array probe, attached to a high-resolution ultrasound machine (Vivid 7 Pro; GE) as previously described. 9,11 The right brachial artery was longitudinally imaged above the antecubital fossa in a supinated position of the forearm. A pneumatic cuff was placed around the forearm, and after the initial measurements at resting conditions, the cuff was rapidly inflated to 250 mm Hg for 5 minutes and subsequently deflated.…”
Section: Methodsmentioning
confidence: 99%
“…Analysis was further adjusted for a prespecified set of confounders, including maternal age, race, parity, weight, height, mean arterial pressure, heart rate and time elapsed from delivery to second visit. To ensure normality of the distribution of dependent variables in linear mixed models, the analysis was repeated after inverse ranking normalization of maternal cardiac markers 15 .…”
Section: Discussionmentioning
confidence: 99%